Brother FAX100 Service Manual page 101

Table of Contents

Advertisement

Selector
No.
CCD manufacturer setting
1
2
Not used.
3
ACS* check sheet output
4
function on/off key
ACS* check sheet output
5
function
6
Registration of station ID
7
Tone sound monitoring
8
Selector 1:
CCD manufacturer setting
Reserved for future variation of CCD.
Selector 4:
ACS check sheet output function on/off key
If this selector is set to "0" (Operative), the user can toggle the ACS check sheet output func-
tion on and off by pressing the right and left arrow keys simultaneously. If it is set to "1"
(Inoperative), the user cannot toggle the ACS check sheet output function from the control
panel so that the setting specified by selector 5 becomes effective.
Selector 5:
ACS check sheet output function
When selector 4 is set to "0", the setting specified by this selector becomes the default state
of the ACS check sheet output function. When selector 4 is set to "1", the setting specified
by this selector becomes permanently effective.
Selector 6:
Registration of station ID
Setting this selector to "0" permits the registration of station ID for Austrian and Czecho ver-
sions.
Selectors 7 and 8: Tone sound monitoring
These selectors sets monitoring specifications of the tone sound inputted from the line.
WSW18
(Function setting 3)
Function
V – 49
Setting and Specifications
Fixed to 1.
0: Operative
1: Inoperative
0: ON
1: OFF
0: Permitted
1: Prohibited
No. 7
8
0 X
:
No monitoring
1
0
:
Up to phase B at the
calling station only
1
1
:
All transmission phases
both at the calling and
called stations
* ACS: Anti-curl system