High Altitude Operation - Honda EG5000X Owner's Manual

Hide thumbs Also See for EG5000X:
Table of Contents

Advertisement

3. Move the fuel volve to the OFF position.
FUEL VALVE
l
High
altitude
operation
At high altitude, the standard
carburetor
air-fuel mixture will be excessively
rich.
Performance
will decrease,
and fuel consumption
will increase.
High altitude
performance
can be improved
by installing
a smaller diameter
main
fuel jet in the carburetor
and readjusting
the pilot screw.
If you always operate the
generator
at altitudes
higher than 6,000
feet above sea level, have your authorized
Honda Generator
dealer perform these parburetor
modifications.
Even with suitable carburetor
jetting,
engine horsepower
will decrease approximatery
3.5% for each 1,000 foot increase in altitude.
The affect of altitude.on
horsepower
will be greater than this if no carburetor
modification
is made.
'6
CAUTION
: Operation
of the generator
at an altitude
lower
than
the carburetor
is
jetted
for may
result
in reduced
performance,
overheating,
and
serious
engine
damage
caused
by an excessively
lean
air/fuel
mixture.