Unit Load Worksheet

1. Number of modules in carrier (excluding power
supply and processor):
If fewer than 5, auxiliary power is not
required.
If 5 or 6, continue to Step 2.
2. Key or Behind Switch mode only:
Indicate configuration of lines; then go to Step 5.
3. Hybrid/PBX mode only:
Do all modules in the carrier have MLX and/or
analog multiline telephone jacks?
If no, auxiliary power is not required.
If yes, continue to Step 4.
4. Hybrid/PBX mode only:
Calculate the total number of MLX and analog
multiline telephones.
Number of MLX-20L consoles connected to
modules in the carrier
Number of MLX-28D consoles connected to
modules in the carrier
Number of 34-button analog multiline telephones
connected to modules in the carrier
Total of MLX-20L, MLX-28D, and 34-button
analog telephones
If the total is less than or equal to 45,
auxiliary power is not required.
If the total is greater than 45, continue to
Step 5.