Spark Arrester; Fuel Sediment Cup Cleaning; Battery Pack And Charger - DeWalt DG series Instruction Manual

Generator/generator with electric start
Table of Contents

Advertisement

Available languages

Available languages

ClEanInG
WARNING: When cleaning, use only mild soap and a damp cloth
on plastic parts. Many household cleaners contain chemicals which
could seriously damage plastic. Also, do not use gasoline, turpentine,
lacquer, paint thinner, dry cleaning fluids or similar products which may
seriously damage plastic parts. Never let any liquid get inside the tool;
never immerse any part of the tool into a liquid.
The generator should be kept clean and dry at all times. The generator
should not be stored or operated in environments that include exces-
sive moisture, dust or any corrosive vapors. If these substances are
on the generator, clean with a cloth or soft bristle brush. Do not use a
garden hose or anything with water pressure to clean the generator.
Water may enter the cooling air slots and could possibly damage the
rotor, stator and the internal windings of the alternator.

Spark Arrester

WARNING: Risk of explosion or fire.
DO NOT operate generator without
spark arrestor (TT).
WARNING: If the engine has been
running, the muffler will be very hot. To
reduce the risk of injury, allow engine to
cool before proceeding.
notE: The spark arrester must be
serviced every 100 hours to maintain
its efficiency.
1. Remove the spark arrestor screws
(UU)
and
remove
the
arrestor.
2. Use brush to remove carbon
deposits from the spark arrester
screen. Inspect the spark arrester
screen for holes or tears. Replace
the spark arrester if necessary.
UU
TT
spark
TT
WARNING: Always wear certified safety equipment: ANSI Z87.1 eye
protection (CAN/CSA Z94.3) with side shields when removing carbon
deposits.

Fuel Sediment Cup Cleaning

The sediment cup prevents dirt or water, which may be in the fuel tank
from entering the carburetor. If the engine has not been run for a long
time, the sediment cup should be cleaned.
1. Turn the fuel shut-off valve (K) to the
OFF position (horizontal to the ground).
Remove the sediment cup (QQ), O-ring
(RR) and screen (SS) as shown.
2. Clean the sediment cup, O-ring and
screen in nonflammable or high flash
point solvent.
3. Reinstall O-ring , screen and sediment
cup.
4. Turn the fuel shut-off valve to the OPEN
position and check for fuel leaks.

Battery Pack and Charger

CHarGEr ClEanInG InStruCtIonS
WARNING: Shock hazard. Disconnect the
charger from the AC outlet before cleaning.
Dirt and grease may be removed from the
exterior of the charger using a cloth or soft non-metallic brush. Do not
use water or any cleaning solutions.
Engine
See engine's instruction manual for correct procedure.
TrAnSPorTInG
WARNING: Units are heavy. Observe safe lifting procedures when
transporting.
Before transporting generator, make sure to:
25
K
SS
RR
QQ

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents