DeWalt DG series Instruction Manual page 18

Generator/generator with electric start
Table of Contents

Advertisement

Available languages

Available languages

Chargers
DG4400B, DG4400BC, DG6300B,
DG6300BC, DG7000B, DG7000BC
The 18V battery pack uses an 18V D
battery can also be charged in D
Chargers or Vehicular 12V charger. Be sure to read all safety instruc-
tions before using your charger. Consult the chart at the end of this
manual for compatibility of chargers and battery packs.
Add Engine oil and Fuel
IMPORTANT! The engine IS NOT filled with oil from the factory. Oil
must be added to the engine before operating or damage to engine
may occur.
aDD EnGInE oIl
See engine's instruction manual for correct procedure.
aDD fuEl to EnGInE (fIG. 1)
WARNING: Risk of explosion or fire. Gasoline vapor is highly flam-
mable. Refuel outdoors preferably or only in well-ventilated areas. Do
not refuel or check gasoline level while the engine is running. Do not
store, spill or use gasoline near an open flame, a source of sparks
(such as welding), or near operating electrical equipment. Do not
smoke when filling fuel tank.
1. Remove fuel cap (G).
2. Add fresh, clean, regular unleaded gasoline with a minimum of 86
octane to the fuel tank (H). notE: Do not mix oil with gasoline.
WARNING: Never fill fuel tank completely. Do
not fill above the shoulders on the debris screen
(NN) as shown to provide space for fuel expan-
sion. Wipe any fuel spillage from engine and
equipment before starting engine.
3. Replace the fuel cap on the tank. Turn the
cap clockwise until it stops.
WALT Charger (included). The
e
WALT 1 Hour Chargers, 15 Minute
e
NN
FEATurES (FIG. 1, 2)
EnGInE SWItCH
The engine switch (S) must be in the ON position to start. To stop the
engine, place switch in the OFF position. See Starting and Stopping
under Operation for complete starting and stopping instructions.
ElECtrIC Start
DG4400B, DG4400BC, DG6300B,
DG6300BC, DG7000B, DG7000BC
On these generators, the engine switch (S) can be placed in three
positions; OFF, ON and START. See Starting under Operation for
complete starting instructions.
18V BattErY paCk anD CHarGEr
The DG4400B, DG4400BC, DG6300B, DG6300BC, DG7000B and
DG7000BC models have an electric start feature that uses an 18V
battery pack (F) to start the engine. The battery pack is charged by
using the charger. See Charger procedure under Assembly for charg-
ing procedure.
MaIn BrEakEr
The main breaker (T) protects the alternator. Overloading the gen-
erator will trip the main circuit breaker. A short circuit in an electrical
device being powered can also trip the main circuit breaker. If the main
breaker trips:
1. Disconnect the electrical loads from all receptacles.
2. Place the main circuit breaker (T) in the OFF position and then
back into the ON position to reset.
IMportant: If the main breaker turns to the OFF position when no
electrical loads are connected, contact a D
ter or a D
WALT authorized service center.
e
18
WALT factory service cen-
e

Hide quick links:

Advertisement

Table of Contents
loading