Inspect Spark Arrester Screen; Storage - DeWalt DXGNR 6500 Instruction Manual

Hide thumbs Also See for DXGNR 6500:
Table of Contents

Advertisement

Available languages

Available languages

Maintenance

Inspect Spark Arrester Screen

Hot Surfaces. When operating
WARNING
machine, do not touch hot surfaces.
Keep machine away from combustibles during use. Hot
surfaces could result in severe burns or fire.
Loosen clamp (A) and remove screw.
1.
Inspect screen (B) and replace if torn, perforated or other-
2.
wise damaged. If screen is not damaged, clean with com-
mercial solvent.
Replace spark arrestor cone (C) and screen (B). Secure
3.
with clamp and screw.

Storage

General
It is recommended to start and run the generator for 30
minutes, every 30 days. If this is not possible, refer to the
following list to prepare unit for storage.
DO NOT place a storage cover on a hot generator. Allow
unit to cool to room temperature before storage.
DO NOT store fuel from one season to another unless
properly treated.
Replace fuel container if rust is present. Rust in fuel will
cause fuel system problems.
Cover unit with a suitable protective, moisture resistant
cover.
Store unit in a clean and dry area.
Always store generator and fuel away from heat and igni-
tion sources.
20
C
A
B
000586
Prepare Fuel System/Engine for Storage
Fuel stored over 30 days can go bad and damage fuel
system components. Keep fuel fresh, use fuel stabilizer.
If fuel stabilizer is added to fuel system, prepare and run
engine for long term storage. Run engine for 10-15 min-
utes to circulate stabilizer throughout fuel system. Ade-
quately prepared fuel can be stored up to 24 months.
If fuel has not been treated with fuel sta-
NOTICE:
bilizer, it must be drained into an
approved container. Run engine until it stops from lack of
fuel. Use of fuel stabilizer in fuel storage container is rec-
ommended to keep fuel fresh.
Change engine oil.
1.
Remove spark plug.
2.
Pour tablespoon (5-10cc) of clean engine oil or spray a suit-
3.
able fogging agent into cylinder.
Vision Loss. Eye protection is
WARNING
required to avoid spray from spark
plug hole when cranking engine. Failure to do so could
result in vision loss.
Pull starter recoil several times to distribute oil in cylinder.
4.
Install spark plug.
5.
Pull recoil slowly until resistance is felt. This will close
6.
valves so moisture cannot enter engine cylinder. Gently
release recoil.
Change Oil
Change engine oil before storage. See, subsection
Change Engine Oil
.
Owner's Manual for Portable Generator

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxgnr 8000

Table of Contents