C.1.6 DEFROSTING
- Automatic defrosting
The appliance is equipped with an automatic defrost function.
This function is indicated by the "dEFr" indicator light.
Defrost water is routed to a bowl, from where it evaporates
automatically.
- Manual defrosting
The defrost cycle can be activated manually by pressing the
MANUAL DEFROST/UP button for 5 seconds
During this function the "dEFr" indicator light stays on.
C.1.7 ALARMS
C.1.7.1 General description
We have available in the electronic board 2 types of alarm
system:
- the HACCP
- the SERVICE ALARMS
The HACCP stores and manages the MAXIMUM CHAMBER
HIGH TEMPERATURE ALARMS.
The SERVICE ALARMS stores and manages all the alarms
available in the electronic board (except the "chamber high
temperature" alarm).

HACCP

C.1.7.2 HACCP
· ALARM CONDITIONS
- the display shows an alarm by the label "TEMP"
- pushing
HACCP
you get information on maximum temperature, time and date
(day, month and year) whwn alarm occured.
There are two possible situations:
a) the alarm is running
b) the alarm has occured
a) the alarm is running
77˚/25˚ Temperature ˚F/˚C
68˚/20˚
59˚/15˚
50˚/10˚
41˚/5˚
17:05
Critical temperature
Critical temperature
46
HOW TO CHECK IT?
display:
rolling label
i.e. "TEMP 78.8F / 26C"
buzzer:
sound alarm ON
WHAT IS RECORDED?
HACCP
Press
: the buzzer goes OFF; then press again
for 5 seconds and the alarm is shown (AL1).
HACCP
Press
again: temperature, starting time and
date are shown by a rolling label: "TEMP 78.8F/26C Start 17.05
10-10-99 End----".
b) the alarm has occured
77˚/25˚ Temperature ˚F/˚C
68˚/20˚
59˚/15˚
50˚/10˚
41˚/5˚
16:00
17:00 18:00
HOW TO CHECK IT?
display:
is showing the label "TEMP"
buzzer:
sound alarm ON
WHAT IS RECORDED?
HACCP
Press
: the buzzer goes OFF; then press again
for 5 seconds and the alarm is shown (AL1).
HACCP
Press
again: maximum temperature inside,
starting and ending time and date of the alarm are shown by a
rolling label: "TEMP 78.8F/26C Start 17.05 10-10-99 End----".
To have access to recorded HACCP alarms press
HACCP
button for 4 seconds; now the display shows
HISt and then AL_1 (symbol of the alarm); this shows the last
maximum chamber temperature alarm stored in the PCB.
HACCP
Press
button to display the value of last maxi-
mum chamber temperature alarm. Now in the display we see:
- TEMP 78.8F/26C (type and value of maximum chamber
temperaturealarm)
Critical temperature
Critical temperature
time
19:00 20:00 21:00 22:00