pressed board: protective surround elements
B.1.2 POSITIONING
Install the equipment, taking all the safety precau-
tions required for this type of operation, also
respecting the relevant fire-prevention instruc-
tions.
Place the appliance in a ventilated room and away
from heat sources such as radiators or air-condi-
tioning systems, in order to allow the cooling of the
refrigerating unit components.
Never cover the condenser, not even temporarily,
as this may jeopardise the operation of both the
condenser and the appliance.
Make sure to position the appliance taking into consideration
the space needed for door opening.
Pay particular attention to levelling of the floor on which the
appliance stands, in order to ensure its optimal operation.
IMPORTANT:
level the appliance, otherwise its operation could be compro-
mised.
Use the height-adjustable feet to make sure the appliance is
level, and at the same time check that the door closes properly.
For trouble-free operation of the appliance, it is recommended
that a gap of at least 19.68"/ 500mm be left between the appli-
ance and the ceiling.
Should the appliance be installed in rooms where there are
corrosive substances (chlorine, etc.), it is advisable to go over
all the stainless steel surfaces with a cloth coated with vaseline
oil, in order to form a protective film.
The maximum ambient temperature at which the appliances
may operate is +109.4°F/+43°C.
Note: the power plug should be accessible even after having
placed the appliance in its final position for installation.
B.1.3 REVERSING OPENING OF DOORS (Fig.5)
Single-door refrigerated cupboards are normally supplied with
right opening.
When changing to left opening, proceed as follows:
• disconnect from the power supply;
• open the control panel, loosening the 2 screws located be-
tween
the panel and the door;
• undo the 2 screws fixing bracket "A" and the screw fixing hinge
"B" (Detail 1);
• remove the door, the hinge "B" and the component "E", then
reverse their assembly;
• remove the lower bracket "D", refitting it in the special seat on
the opposite side (Detail 2);
• position the door on the lower bracket "D";
• position the upper bracket "A" between the door and the top
of the equipment, screwing the fixing bolts;
• before tightening the screws, align the door with respect to the
side of the unit, operating the lower and upper brackets and
checking correct fitting of the seal on all sides of the unit;
• then tighten the bracket fixing bolts;
• reconnect the power supply.
B.1.4 REVERSING OPENING OF HALF DOORS (Fig.6)
Single-door refrigerated cupboards are normally supplied with
right opening.
When changing to left opening, proceed as follows:
• disconnect the power supply;
• open the control panel, loosening the 2 screws located be-
tween the panel and door;
• undo the 2 fixing screws of bracket "A" and the fixing screw of
hinge "B";
• remove the door;
• remove the middle bracket "F" and remove the bottom door;
• remove the lower bracket "A" refitting it on the opposite side
in the special seat;
• position the bottom door on the lower bracket "A";
• fix the middle bracket "F";
• position the top door on the middle bracket "F";
• fix the upper bracket "A" between the door and the roof of the
unit, screwing the fixing bolts;
• before tightening the screws, align the door with the side of the
cabinet by moving the lower and upper brackets, checking
correct fitting of the seal on all sides of the cabinet;
• then tighten the bracket fixing bolts.