Choosing A Suitable Site - 3Com 3CR17561-91-US - Switch 4500 26PORT Managed 24 10/100 2 Gbe Stackable RJ45 Getting Started Manual

4500 series switch
Table of Contents

Advertisement

Choosing a Suitable
Site
The Switch is suited for use on a desktop, either free standing or
mounted in a standard 19-inch equipment rack. Alternatively, the Switch
can be mounted in a wiring closet or equipment room. A rack-mounting
kit containing two mounting brackets is supplied with the Switch.
CAUTION: Ensure that the ventilation holes are not obstructed.
When deciding where to position the Switch, ensure that:
Cabling is located away from:
sources of electrical noise such as radios, transmitters and
broadband amplifiers.
power lines and fluorescent lighting fixtures
The Switch is accessible and cables can be connected easily.
Water or moisture cannot enter the case of the Switch.
Air flow is not restricted around the Switch or through the vents in the
side of the Switch. 3Com recommends that you provide a minimum of
25mm (1in.) clearance.
Air temperature around the Switch does not exceed 40
If the Switch is installed in a 19-inch rack or closed assembly its local air
temperature may be greater than room ambient temperature.
The air is as free from dust as possible.
The unit is installed in a clean, air conditioned environment.
No more than eight Switch units are placed on top of one another, if
the units are free-standing.
The Switch is situated away from sources of conductive (electrical)
dust, for example laser printers.
The AC supply used by the Switch is separate to that used by units
that generate high levels of AC noise, for example air conditioning
units and laser printers.

Choosing a Suitable Site

(104
°C
25
F).
°

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents