3-5. Setting The Adjustment Values
3-5-1. Hi-MD3 setting
Preparation:
1. Perform calculation every item based on the data given by the
Hi-MD3 adjustment disc by referring to the following table.
(Round off the value in decimal place)
2. Convert the calculated value into hexadecimal number.
Note: The Hi-MD3 adjustment parameters vary depending on the disc,
and therefore use the parameters of the disc used when performing
the adjustment.
Item No.
Calculating formula (*3)
0211
Pr_nominal / 0.05
(*1)
Por / 0.05
0212
Kr ( 100)
0213
Pw_nominal / 0.05
(*2)
Ppw / 0.05
0214
Kw ( 100)
0215
Prmin / 0.05
0216
Pwmin / 0.05
*1) If the "Pr_nominal" value is indicated, use the "Pr_nominal" value
and not used "Por" value.
*2) If the "Pw_nominal" value is indicated, use the "Pw_nominal" value
and not used "Ppw" value.
*3) Round off after the decimal point.
Table 3-5-1. Hi-MD3 adjustment parameter
Example of Calculation:
Item No.
Parameter
0211
Pr_nominal
2.50 mW
0212
Kr
0.3 %/ C
0213
Pw_nominal 7.35 mW
0214
Kw
0.4 %/ C
0215
Prmin
1.9 mW
0216
Pwmin
5.8 mW
Procedure:
1. Enter the test mode (Display Check mode).
2. Press the [VOL+] key to enter the Manual mode.
key once, press the [VOL+] key once, and press
3. Press the
>
the
key once again to display as follows.
>
0210
4. Press the
key once to select the item number 0211.
>
5. Adjust with [VOL+]/[VOL--] keys so that the adjustment value
of EL becomes calculated value.
6. Press the
key to write the adjusted value.
X
7. Press the
key to next item.
>
8. Repeat adjustment from step 4 until item number 0216.
Result
Decimal
Hexadecimal
50
32h
30
1Eh
147
93h
40
28h
38
26h
116
74h
DiscPr
3-5-2. Destination setting
Procedure:
1. Enter the test mode (Display Check mode).
2. Press the [VOL+] key to enter the Manual mode.
3. Press the
key five time to select the item number 0113
>
and display as follows.
0113
adjustment value (hexadecimal)
4. Adjust with [VOL+]/[VOL--] keys so that the adjustment value
of EL becomes "01" (US, Canadian models) or "81" (AEP
model).
5. Press the
key to write the adjusted value.
X
6. Press the
key four times and back to the Display Check
x
mode.
MZ-RH1
******