Sony Walkman MZ-RH1 Service Manual page 15

Service manual
Hide thumbs Also See for Walkman MZ-RH1:
Table of Contents

Advertisement

5-2. Error Code of The Self-Diagnosis Result Display
Mode
Error display code
0000
No error
0001
Attempt to access an abnormal address
0002
High temperature detected
0003
Focus error (no change)
0004
Abnormal rotation of disc
0005
Fault of disc discriminate
0006
Error of access loop (no change)
0007
Error of access loop (with change)
0008
Could not read address
0009
Focus error (with change)
0012
Could not read data with SYNC
0013
TOC address data error
0032
Focus error, ABCD offset error
0033
Tracking error, offset error
0034
X1 tracking error, Tracking error, offset error
Error display code
Addition information when error occurs
0000
0000
0001
Illegal cluster specified when error occurs
0002 to 0034
Total recording time when error occurs
5-3. Clear The Total Recording Time
After replacing the optical pick-up, clear the total recording time.
1. Enter the test mode (Display Check mode).
2. Press the
key to activate the Self-Diagnosis Result Display
>
mode.
3. Press the [VOL--] key once to display the total recording time
indication.
4. Press the
key and display "ClrOK?".
X
5. Press the
key again to display "RecT 0" and clear the total
X
recording time.
Description
6. KEY CHECK MODE
This mode is used for key check.
Operation of The Key Check Mode
1. Enter the test mode (Display Check mode).
2. Press the [DISPLAY/MENU] key to activate the Key Check mode
where the LCD displays as shown below.
0100
"$$$$$$" : Pressed key name.
When remote commander key is pressed, display becomes
as "r$$$$$".
"##"
: Key voltage of remote commander. (Hexadecimal number)
3. To release the Key Check mode, open the upper panel and
return to the Display check mode.
MZ-RH1
$$$$$$ # #
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mz-rh1

Table of Contents