PROGRAMMING

4
Confi gure the KPR2000.
Change the configure settings according to your application (optional). Multiple configuration settings can be changed at one time: enter
program mode, change desired settings, then exit program mode.
SET MASTER CODE
The 6 digit Master Code is used to prevent unauthorized access to the
system. To interface with the KPR2000, the manager will need a Master
Code (factory default code: 888888). We highly recommend immediate
update and recording of your Master Code.
Programming Step
Keystroke Combination
✱ (Master Code) #
1. Enter Program Mode
0 (New Code) # (New Code) #
2. Update Master Code
3. Exit Program Mode
SET ACCESS CONFIGURATION
There are 3 types of access configurations for the KPR2000:
• Card or PIN (Default): The User must present a valid Wiegand Card to
the KPR2000 or enter their PIN code followed by the # key, in order to
be granted access.
• Card Only: The User must present a valid Wiegand Card to the
KPR2000 in order to be granted access. The facility code and the ID
number are both read and validated as one block of Wiegand data.
• Card + PIN: The User must first present a valid Wiegand Card to the
KPR2000 and then enter their PIN code followed by the # key, in order
to be granted access.
Programming Step
Keystroke Combination
✱ (Master Code) #
1. Enter Program Mode
2. Card Only
3 0 #
OR
2. Card + PIN
3 1 #
OR
2. Card or PIN
3 2 #
3. Exit Program Mode
SET RELAY CONFIGURATION
The relay configuration sets the behavior of the output relay on activation.
Programming Step
Keystroke Combination
✱ (Master Code) #
1. Enter Program Mode
2. Pulse Mode
4 (1-99) # The relay time is 1-99 seconds
(default is 5 seconds)
OR
4 0 # Sets the relay to ON/OFF latch mode
2. Latch Mode
3. Exit Program Mode
SET WIEGAND INPUT/OUTPUT OPTIONS
The KPR2000 offers input and output for industry standard Wiegand
devices (refer to Specifications). Default is 26 bit.
Programming Step
Keystroke Combination
✱ (Master Code) #
1. Enter Program Mode
2. Set Wiegand Format
9 (Bit Format) # Bit Format = Valid 2 digit
format (example: 26, 30, or 34)
3. Exit Program Mode
SET DOOR OPEN TOO LONG (DOTL) ALARM
This setting requires an external sensor input. The alarm output timing
can be set from 1-3 minutes (default is 1 minute). Factory default is OFF.
Programming Step
1. Enter Program Mode
2. DOTL Alarm OFF
OR
2. DOTL Alarm ON
OR
2. DOTL Output Timing
3. Exit Program Mode
SET STRIKE-OUT ALARM
The strike-out alarm will engage after 10 failed card/PIN attempts. Factory
default is OFF. The strike-out alarm can be set to deny access for 10
minutes after engaging or it can be set to disengage only after entering a
valid master code or card.
Programming Step
1. Enter Program Mode
2. Strike-Out OFF
OR
2. Strike-Out ON
OR
2. Strike-Out ON
3. Exit Program Mode
SET AUDIBLE AND VISUAL RESPONSE
Factory default is ON.
Programming Step
1. Enter Program Mode
2. Control Backlight
OR
2. Control LED
OR
2. Control Sounds
3. Exit Program Mode
5
Keystroke Combination
✱ (Master Code) #
6 0 #
6 1 # (Alarm sounds for 1 minute)
9 (1-3) #
Keystroke Combination
✱ (Master Code) #
7 0 # (factory default)
7 1 # Access will be denied for 10 minutes
7 2 # Enter Master Code or Valid Card to
silence
Keystroke Combination
✱ (Master Code) #
ON = 7 5 #
OFF = 7 4 #
ON = 7 7 #
OFF = 7 6 #
ON = 7 9 #
OFF = 7 8 #