Troubleshooting
Identifying LCD-Indicated Conditions

Chassis Codes

Table 3-1 lists all of the chassis codes for the J6700 workstations.
Table 3-1. Chassis Codes for J6700 Workstations
Ostat
Code
FRU
FLT
1n01
SYS BD
FLT
1n02
SYS BD
FLT
1n03
SYS BD
FLT
1n04
SYS BD
FLT
1n05
SYS BD
FLT
1n06
SYS BD
FLT
1n07
SYS BD
FLT
1n08
SYS BD
FLT
1n09
SYS BD
FLT
1n0A
SYS BD
FLT
1n0B
SYS BD
FLT
1n0C
SYS BD
FLT
1n0D
SYS BD
FLT
1n0E
SYS BD
FLT
1n0F
SYS BD
FLT
1n10
SYS BD
FLT
1n11
SYS BD
46
Message
HPMC occurred
powerfail intrpt
recvry cntr trap
external intrrpt
LPMC occurred
ITLB mis/Ipg flt
I mem prot trap
illegal inst trp
break instr trap
privilgd op trap
privlgd reg trap
overflow trap
conditional trap
assist exep trap
DTLB mis/Dpg flt
non-acc ITLB mis
non-acc DTLB mis
Description
CPU n detected an unexpected HPMC.
CPU n detected an unexpected power fail
interrupt.
CPU n detected an unexpected recovery
counter trap.
CPU n detected an unexpected external
interrupt.
CPU n detected an unexpected LPMC.
CPU n detected an unexpected ITLB miss
or instruction page fault.
CPU n detected an unexpected instruction
memory protection trap.
CPU n detected an unexpected illegal
instruction trap.
CPU n detected an unexpected break
instruction trap.
CPU n detected an unexpected privileged
operation trap.
CPU n detected an unexpected privileged
register trap.
CPU n detected an unexpected overflow
trap.
CPU n detected an unexpected conditional
trap.
CPU n detected an unexpected assist
exception trap.
CPU n detected an unexpected DTLB
miss or data page fault.
CPU n detected an unexpected non-access
ITLB miss fault.
CPU n detected an unexpected non-access
DTLB miss or data page fault.