Online/activity
Fault/UID LED
LED (green)
(amber/blue)
Flashing
Amber, flashing
irregularly
regularly (1 Hz)
Flashing
Off
irregularly
Off
Steadily amber
Off
Amber, flashing
regularly (1 Hz)
Off
Off
Interpretation
The drive is active, but a predictive failure alert has been
received for this drive. Replace the drive as soon as possible.
The drive is active and it is operating normally.
A critical fault condition has been identified for this drive and
the controller has placed it offline. Replace the drive as soon as
possible.
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.
The drive is offline, a spare, or not configured as part of an
array.