SW0:admin> firmwaredownload
Server Name or IP Address: 123.456.78.90
User Name: user
File Name: /v4.2.0/release.plist
Password: xxxxxx
Full Install (Otherwise upgrade only) [Y]:
Do Auto-Commit after Reboot [Y]:
Reboot system after download [N]: y
Start to install packages......
dir ##################################################
terminfo
##################################################
<some output not shown>
glibc ##################################################
sin ##################################################
Write kernel image into flash.
file verification SUCCEEDED
Firmwaredownload completes successfully.
SW0:admin>
For more information about the firmwareDownload command, refer to the HP
StorageWorks command reference guide for the Fabric OS version running on your switch.
5.
Verify that the reboot is complete and the CP cards have achieved failover redundancy:
a. Wait until the Status LEDs on both CP cards are off.
b. Enter the haShow command and verify that the command output includes HA
Enabled, Heartbeat Up, State Synchronized; If not, wait a minute and
reenter the command, until you have verified that redundancy is achieved.
6.
Enter the version or firmwareShow command to verify that the firmware version has
been updated.
7.
Create a serial connection to the new CP card:
a. Disable any serial communication programs running on the workstation (such as
synchronization programs).
b. Connect a serial cable to the terminal serial port (10101 Console Port).
c. Connect the other end of that serial cable to a serial port on the workstation.
Core Switch 2/64 and SAN Director 2/128 installation guide