HP StorageWorks 2/64 - Core Switch Installation Manual page 106

Hp storageworks core switch 2/64 and san director 2/128 installation guide (aa-rvusc-te, january 2005)
Hide thumbs Also See for StorageWorks 2/64 - Core Switch:
Table of Contents

Advertisement

2.
Enter the slotShow command.
The command output should show the new CP card as enabled.
swDir:admin> slotShow
Slot
swDir:admin>
3.
Determine the firmware version by entering the firmwareShow command.
swDir:admin> firmwareshow
Primary partition:
Secondary Partition:
swDir:admin>
4.
If the firmware version of the replacement card does not match that of the active CP card,
bring the replacement card to the same firmware level as the active card. Check with the
switch supplier for supported versions.
Download the firmware, using either of the following command options:
• firmwareDownload to download the firmware to both CP cards at the same time.
Enter all requested information and choose the reboot option.
• firmwareDownload -s to download the firmware to only one of the CP cards. Enter
all requested information and choose the reboot option.
106
Installing FRUs
Blade Type
ID
---------------------------------
1
SW BLADE
2
SW BLADE
3
SW BLADE
4
SW BLADE
5
CP BLADE
6
CP BLADE
7
UNKNOWN
8
SW BLADE
9
SW BLADE
10
UNKNOWN
Status
4 FAULTY
4 DISABLED
4 ENABLED
4 DIAG RUNNING POST2
5 ENABLED
5 ENABLED
VACANT
4 DIAG RUNNING POST1
4 INSERTED, NOT POWERED ON
VACANT
v4.2.0meteor_pit_02_031204_0722
v4.2.0meteor_pit_02_031204_0722

Advertisement

Table of Contents
loading

Table of Contents