HP StorageWorks 2/16 - SAN Switch Installation Manual page 41

Hp storageworks san switch 2/16 v3.1.2 (aa-rr84d-te, may 2004)
Hide thumbs Also See for StorageWorks 2/16 - SAN Switch:
Table of Contents

Advertisement

Note:
different application, consult that application's documentation.
6. Using HyperTerminal (or similar application), configure the Port Settings as
7. Log in to the switch (with administrator privileges). The default administrator
SAN Switch 2/16 Version 3.1.2 Installation Guide
These steps show instructions specific to HyperTerminal. If you are using a
follows:
Bits per second: 9600
Databits: 8
Parity: None
Stop bits: 1
Flow control: None
To configure Port Settings in a UNIX
tip /dev/ttyb -9600
logon is admin and the default password is password.
a. Enter the following at the prompt:
ipAddrSet
b. Enter the following information at the corresponding prompts listed
below:
— Ethernet IP Address [10.77.77.77]:
Enter the new Ethernet IP address.
— Ethernet subnetmask [0.0.0.0]:
Enter the new Ethernet subnetmask.
— Fibre Channel IP Address [none]:
Enter the new Fibre Channel IP address if desired.
— Fibre Channel Subnetmask [none]:
Enter the new Fibre Channel subnetmask if desired.
— Gateway Address [172.17.1.1]:
Enter the new gateway address.
— Set IP address now? [y = set now, n = next
reboot]:
Enter y to set now.
Installing the SAN Switch 2/16
®
environment, enter:
41

Advertisement

Table of Contents
loading