Proto
comment
Fabric OS Command Reference
53-1001764-01
Online
The port is up and running.
Protocol support by GbE port. Valid protocols include the following:
ISCSI
The port supports ISCSI (deprecated).
FCIP
The port supports FCIP.
FCoE
The port supports Fibre Channel over Ethernet.
Optionally displays one of the following:
Copper or Optical
Displays which GbE port is currently active: Copper indicates that the RJ45 GbE
port is currently active. Only copper connections are accepted (default). Optical
indicates that the currently active GbE port accepts both copper and optical
connections (SFPs). This parameter is set by the portCfgGeMediaType
command, and applies only to the ge0 and ge1 ports on the Brocade 7800.
Disabled
The port is disabled. Port disable reasons may be stated in parenthesis:
Disabled (FMS Mode)
The port is disabled and in Ficon Server Management mode.
Disabled (No area available for PID assignment)
The port is disabled because a PID could not be assigned for the stated
reason.
Disabled (persistent)
This port has been disabled with the portCfgPersistentDisable command.
Disabled (Persistently disabled port)
This port has been disabled for unspecified reasons.
Bypassed
The port is bypassed (loop only).
Loopback
The port is in loopback mode.
D_Port
Diagnostic port; displays the world wide name (WWN) of the remote switch.
E_Port
Fabric port; displays the world wide name (WWN) and name of the attached
switch. If the port is configured as an EX_Port, the WWN of the attached switch is
the same as the router.
F_Port
Point-to-point port; displays the WWN of the attached N_Port. If that specific
F_Port receives 1 FDISK frame, switchShow displays the total number of NPIV
Public ports as 1, for example: F_Port 1 NPort + 1 NPIV devices.
G_Port
Point-to-point port, but not yet E_Port or F_Port.
L_Port
Loop port; displays the number of NL_Ports.