PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications
9.5 PC Adjust Status Read Command
9.5.1
CR_FSYNC Command
Command
"CR_FSYNC" [CR]
Details
Get value of Fine Sync
Acceptable
%1
Response
Unacceptable
9.5.2
CR_TDOTS Command
Command
"CR_TDOTS" [CR]
Details
Get value of Total Dots
Acceptable
%1
Response
Unacceptable
9.5.3
CR_CLPPHASE Command
Command
"CR_CLPPHASE" [CR]
Details
Get value of Clamp Phase value
Acceptable
Response
%1
Unacceptable
9.5.4
CR_H-POS Command
Command
"CR_H-POS" [CR]
Details
Get value of Horizontal Position
Acceptable
%1
Response
Unacceptable
9.5.5
CR_V-POS Command
Command
"CR_V-POS" [CR]
Details
Get value of Vertical Position
Acceptable
%1
Response
Unacceptable
"000_%1" [CR]
"0000 – 0031"
"Error Code" [CR] --- When command is not available in the given
condition (such as being selected input)
"?" [CR] --- When unknown command is received
"000_%1" [CR]
"mmmm" – "nnnn"
(mmmm = Display area H + Position H)
(nnnn = Maximum value less than 140 MHz of Dot Clock)
"Error Code" [CR] ------------------------ When command is not
available in the given condition (such as being selected input
"?" [CR] ------------------- When unknown command is received
"000_%1" [CR]
"0000 – 0255"
"Error Code" [CR]
"000_%1" [CR]
"0000 – nnnn"
(nnnn = Total Dots – Display area H)
"Error Code" [CR] ------ When command is not available in the
given condition (such as being selected input
"?" [CR] ------------------- When unknown command is received
"000_%1" [CR]
"0000 – nnnn"
(nnnn = Total Line – Display area V)
"Error Code" [CR] ------ When command is not available in the
given condition (such as being selected input
"?" [CR] --------------------- When unknown command is received