Single Initiator To Single Target Zoning With Fan-In From Multiple Hp 3Par Storage System Ports To One Host Server Port; Single Initiator To Single Target Zoning With Mixed Fan-In And Fan-Out Configurations - HP P10000 Implementation Manual

Hp 3par hp-ux 11i v2, v3 implementation guide (ql226-96021, august 2011)
Hide thumbs Also See for P10000:
Table of Contents

Advertisement

Figure 2 Single Initiator to Single Target Zoning with Fan-Out
NOTE:
A maximum of 64 host server ports can fan-out from a single HP 3PAR Storage System
port.
Single Initiator to Single Target Zoning with Fan-In from Multiple HP 3PAR Storage System Ports to
One Host Server Port
With single initiator to single target zoning, in a fan-in configuration a host server port connects
to many HP 3PAR Storage System ports, as shown in
Figure 3 Single Initiator to Single Host Target Zoning with Fan-In
NOTE:
A maximum of four HP 3PAR Storage System ports can fan-in to a single host server port.

Single Initiator to Single Target Zoning with Mixed Fan-In and Fan-Out Configurations

With single initiator to single target zoning, in a fan-in and fan-out configuration, one HP 3PAR
Storage System connects to multiple host servers.
12
Configuring the HP 3PAR Storage System for Fibre Channel
Figure 3 (page
12).

Advertisement

Table of Contents
loading

This manual is also suitable for:

3par hp-ux 11i v3

Table of Contents