PLC-HP7000L Basic Serial Command Functional Specifications
・ "10" [CR]
Status: Power Failure
When the power supply voltage inside the projector reaches abnormal status, the projector
is automatically turned off.
※ Abnormal power supply voltage includes;
Filter abnormal status
-
Shutter abnormal status
-
The projector returns "10" [CR], which indicates it enters Power OFF status due to Power
Failure.
In this case Fan also stops unlike Cooling Down status.
・ "28" [CR]
Status: Cooling Down in process due to Abnormal Temperature
When the inside temperature rises abnormally high, it automatically starts Cooling Down
operation. The projector returns "28" [CR].
Even if the temperature goes down during this process, the given Cooling Down process is
conducted.
・ "88" [CR]
Status: Standby after Cooling Down due to Abnormal Temperature
When the status becomes Standby after the temperature goes down by Cooling Down
operation invoked due to Abnormal Temperature, the projector returns "88" [CR]. This
indicates Abnormal Temperature caused turning to Standby status.
This status continues until the next operation is started; when Power On is executed, the
projector clears the information of Abnormal Temperature and normal operation starts.
・ "24" [CR]
Status: Power-Save Cooling Down in process
This indicates Power Management in the Setting menu is enabled and Power-Save
Cooling Down operation is in process.
During this time, any Functional Execution Command is invalid.
In this Power-Save Cooling Down function, the status moves to Power Save after the given
Cooling down operation.
Status:
No signal
Response: "00"
No signal status has passed for the time
set by power management timer
Power-Save Cooling Down
"24"
24/27
Power Save
"04"
After about 90 sec.