Advertisement

Other Information
Restore To Default
[NOTE]
1.Behavior at lock modes
Lock Mode
Button Lock
MENU Lock
POWER Lock
Remote control disable
Get-Function Listing
The PC can interrogate the LCD Display for specific information. The Get-Function packet format
consists of 9 bytes which is similar to the Set-Function packet structure. Note that the "Value" byte
is always = 00.
Get-Function description:
Length:
Total Byte of Message excluding "CR"
Display ID
Identification for each of Display.
Command
Identify command type,
Type
"g" (0x67h) : Get Command
"r" (0x72h) : Valid command Reply
"-" (0x2Dh) : Invalid command Reply
Command:
Function command code: One byte ASCII code
Value[1~3]:
Three bytes ASCII that defines the value
CR
0x0D
(Continued)
~
7E
000
Behavior
1. Lock all buttons of front panel and RCU, except for "Power"
2. All the SET functions should be workable via RS32, even the ones with
according hot key in RCU like Mute,...etc.
1. Lock "MENU' key of front panel and RCU
2. The Factory and Hospitality modes should not be blocked for the
model using MENU-combined key to enter these two modes. Alternative
approach will be indicated separately if any limitation by model.
1. Lock "POWER" key of front and RCU.
2. The SET_POWER on/off should be workable via RS232, but does not
mean the POWER lock will be released under this case.
3. Can not be un-locked by reset in OSD setting
4. Will auto AC power-on in power-lock
5. Under power-lock, the set will not enter power saving when no PC signal
and neither not turn off when no other video signals after 15min.
Lock the keys on RCU, but keep the buttons of front panel workable.
Rests Display to factory setting