Loosen the three screws on the lamp
then pull out the lamp by its grab.
Screws
Screws
Note
Lamp 1 and Lamp 2 are of the same type.
They are installed in opposite vertical
orientation to each other. When removing,
note the orientation of each lamp.
4
Insert the new lamp all the way in until
it is securely in place. Tighten the
three screws.
5
Close the lamp cover and tighten the
two screws.
Notes
• The lamp cover cannot be closed if the
screws that secure the lamps are
loosened.
• Be sure to install the lamp and lamp
cover securely as it was. If not, the
projector cannot be turned on.
When lamp replacement is completed
Replace the air filter cartridge (page 38).
Disposal of the used lamp
For the customers in the USA
Lamp in this product contains mercury.
Disposal of these materials may be
regulated due to environmental
considerations. For disposal or
recycling information, please contact
your local authorities or the
Telecommunications Industry
Association (www.eiae.org).
Grab
Replacing the Lamp
37