Messages List - Sony VPL-FH500L Operating Instructions Manual

Operating instructions
Hide thumbs Also See for VPL-FH500L:
Table of Contents

Advertisement

Messages List

When any of the messages listed below appears on the projected image, address the problem in
accordance with the table below.
Message
High temp.! Lamp off in
1 min.
Frequency is out of
range!
Please check Input-A
Signal Sel.
Please replace Lamp 1
and Filter.
Please replace Lamp 2
and Filter.
Please replace Lamp 1,
Lamp 2 and Filter.
Projector temperature is
high. High Altitude
Mode should be "On" if
the projector is being
used at high altitude.
Not applicable!
The panel keys are
locked!
Lens Control is locked!
Error occurred on
Lamp1.
Lamp 2 is lit.
Error occurred on Lamp
2.
Lamp 1 is lit.
The shutter did not
work.
Meaning/Remedy
Check the items below.
• Check to see if nothing is blocking the ventilation holes.
• Check to see if the air filter is not clogged.
• Check if "Installation Attitude" on the Installation menu is
correctly selected.
Change the output setting of the connected equipment to one
for signals supported by the projector.
Set "Input-A Signal Sel." to "Auto" or select the input signal
type to suit to the input signal.
Replace the lamp with a new one and replace the air filter. The
message appears whenever you turn on the power until you
replace the lamp.
At an altitude of 1,500 m or higher, if you are not using the
projector, check the items below.
• Check that nothing is blocking the ventilation holes.
• Check that the air filter is not clogged.
• Check if "Installation Attitude" on the Installation menu is
correctly selected.
Invalid key pressed.
"Panel Key Lock" is set to "On."
"Lens Control" is set to "Off."
An error occurred in the lamp and another lamp is lit.
Consult with qualified Sony personnel.
Page
3, 26,
38
51
25
36, 38
3, 26,
38
5
23
23
33
Messages List