Convoclean Automatic Cleaning System (Optional) - Cleveland Convotherm OEB-20.20 Service And Parts Manual

Combination oven-steamer
Hide thumbs Also See for Convotherm OEB-20.20:
Table of Contents

Advertisement

C. CONVOClean Automatic Cleaning System (optional):
NOTES:
Do NOT interrupt the automatic cleaning process. Interrupting and restarting the
Automatic Cleaning System with the ON/OFF key may start a 6 minute forced rinsing of
the oven chamber to remove any CONVOClean and CONVOCare residue when the
ON/OFF key is turned back ON. The Signal Tone sounds at the end of the forced rinsing
cycle and the Combi is ON.
Do not open the Combi door during the automatic cleaning process, unless the
instruction "Open the door" and "close the door," appears in the display.
Pre-clean manually to save water and CONVOClean by selecting a lower cleaning
setting.
If the security questions are not answered within 5 seconds, the Combi resets itself to the
query level and will not start.
If the message "No cleaner pressure" appears, check that there is enough CONVOClean
and/or CONVOCare in the correct containers. Refill them if necessary (red hose for
CONVOClean, and blue or white hose for CONVOCare).
Always make sure the cleaning agent containers are correctly connected to the Combi
A. See P/N 260AZA, "Instructions for CONVOClean System Start-up Kit," for hose attachment,
solution mixing, and other information.
B. The CONVOClean Automatic Cleaning Process
1. The oven chamber must be cold before starting this process. If the oven chamber is still
hot, the error message, "oven temp too hi / please wait" appears in the display. If this
error message appears, open the Combi door, wait 15 minutes and then try to start the
automatic cleaning process. Repeat as needed.
2. Before starting, remove large pieces food or cooking residue from the oven chamber to
help prevent the drain from becoming blocked.
3. Check the level of Convotherm by Cleveland CONVOClean and CONVOCare.
a. The containers must be full.
b. The suction pipes must be located in the fluid.
c. The hoses must be properly attached to the Combi.
4. Press the Smart Key. Various options appear in the display.
5. Use the Selector Dial to select "CONVOClean system"
6. Confirm by pressing the Smart Key.
7. PRESS the Temperature key and select the cleaning level (1-4) with the Selector Dial.
Approximate run times are listed to help plan use of the CONVOClean system. Times
may vary by +/- 15 minutes.
1
"Light Soiling"
2
"Medium Soiling"
CAUTION
CONVOClean => RED
CONVOCare => BLUE or WHITE
55 minutes.
1 hour and 30 minutes.
19
.