Maytag MEDE300VW - Performance Series 27 Inch Electric Dryer Use & Care Manual page 14

Performance series
Table of Contents

Advertisement

Available languages

Available languages

3-wire connection:
Power supply cord
Use where local codes permit connecting cabinet-ground conductor to neutral wire.
C
G
F
A. 3-wire
receptacle
(NEMA
type
IO-30R)
B. 3-wire
plug
C. Neutral
prong
D. Spade
termina/5
with
up turned
ends
E. V4" ( 1.9 cm) UL /isted strain
relief
£ Ring tem_ina/s
C. Neutra/
(white
or center
wire)
1.
I.oosen or remove
center
silver-colored
terminal
block
screw.
2.
Connect
neutral
wire (white or center wire)
of power supply
cord to the center; silver-
colored
terminal
screw of the terminal
block.
Tighten
screw.
_E
A. External
ground
conductor
screw
B. Neutral
ground
wire
C. Center
silver-cokJred
terminal
block
screw
D. Neutra/
wire (white
or center
wire)
E. V4" ( 1.9 cm)
UL fisted strain
refief
3.
Connect
the other wires to outer terminal
block
screws. Tighten
screws.
!
!
4.
Tighten
strain relief screws.
5.
Insert tab of terminal
block
cover into slot of dryer rear panel. Secure cover with
hold-
down screw.
6.
You have completed
your electrical
connection.
Now go to "Venting
Requirements."
3-wire connection:
Direct wire
Use where
local codes permit connecting
cabinet-ground
conductor
to neutral wire.
Direct
wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved
if needed.
Strip 3V2' (8.9 cm) of outer covering
from end of cable. Strip insulation
back 1" (2.5 cm). If
using 3-wire
cable with
ground
wire, cut bare wire even with outer covering.
Shape ends of
wires into a hook shape.
i...........'3t
'
'
When
connecting
to the terminal
block,
place the hooked
end of the wire under the screw of
the terminal
block
(hook facing
right), squeeze
hooked
end together
and tighten
screw, as
shown.
1.
I.oosen or remove
center
silver-colored
terminal
block
screw.
14