Troubleshooting (continued)
Problem
Drumlight doesnotfunction,
Possiblecause
Noprogramselected.
Lightbulb defective,light bulb burnedout.
Nopowersupply.
Lightbulb is loose.
"Start/Pause" i ndicatorlight doesnot
Faultin programsequence or malfunction.
illuminate."WrinkleBIocidFinished"
indicatorlights.
Thedisplayshows"000".
Lintfilter LEDis blinkingafterthe lint
Noaction required. Lightwill stop blinking.
filter hasbeencleaned
Display shows....
Placelaundryon dryerrack. Restartprogram.
Unusual n oise: thumpingsound
Dryeris not level.
Unusual n oise: Steadyvibrationd,
rockingof the dryer
Unusual n oise: Rhythmic vibration
Wateris not sprayedintothe unit
duringSteamcycles
Blinkingof lint filter LEDis not an indication of a
problem. It is usedonlyas a reminder.
Laundrydetectedin drum duringwool program
(laundrynoton rack)
Drumsuspension rollersneedtime to warm up.
Laundryballedup causingloadto bounce.
Watertap(s)not turnedon.
Nozzle doesnot spraywateradequately.
Blocked nozzle
LEDor button illuminated on control
Faultcondition
panelwhenCycleSelectoris turnedto
"Off" position
Remedialaction
Selectprogram.
Replace burnedout bulband reinstallthe coveras
directedon page29.
Checkpowersupply.
Remove the bulb coverand if bulb is loose,tighten
bulb.Reinstall t he coveras directed on page29.
Switchoff dryer,leaveto cooldownfor 30 min,
switchon again.
Restartprogram.
Noaction required.As suspension systemrollers
warm up thumpingwill decrease and shouldstop
within 2 to 3 minutesof dryeruse
Levelthe dryer(seeusermanual s ection"Installation
Instructons"
Stopdryer,separateloaditems, restartdryer.
Turnon watertap.
Wipethe outsideof the nozzle with a cloth moistened
with vinegar.If this doesnot restorethe nozzle to
spraying,see "Blockednozzle"remedial a ction
below.
Remove the nozzleusinga 7/16 inch(11 mm)socket
wrench. Placethe nozzle into a container filled with
enoughwhite vinegarto coverthe nozzle.Allowthe
nozzle to soakfor five minuntes, t henscrubthe
nozzle tip gentlywith a toothbrushto removeresidue.
Rinsethe nozzle and reinsertit backinto the dryer
and handtighten,then tighten 1 additional t urn with
the wrench.
Turnoff the circuitbreakerand call Customer Service
(pg.32).