Environmental Requirements - HP AK241A - StorageWorks 8Gb Simple SAN Connection Installation And Reference Manual

Fibre channel switch
Hide thumbs Also See for AK241A - StorageWorks 8Gb Simple SAN Connection:
Table of Contents

Advertisement

Environmental requirements

To ensure proper operation, the switch must not be subjected to environmental conditions beyond those for
which it was tested. The ranges specified in
operating and non-operating conditions.
Table 14
Environmental requirements
Condition
Temperature
Humidity
Altitude
Vibration (IEC 68-2-6)
Shock (IEC 68-2-7)
66
Table 14
Acceptable range during operation
0° to 40°C (32° to 104°F)
15% to 80%, non-condensing
3,048 m (10,000 feet) above sea level 15,240 m (50,000 feet) above sea
5-500 Hz, random, 0.21 Grms, 10
minutes
4 g, 1 1ms, 20 repetitions
identify the acceptable environment for both
Acceptable range during
non-operation
-40° to 70°C (-40° to 158°F)
5% to 90%, non-condensing
level
5-500 Hz, random, 2.1 Grms, 10
minutes
30 g, 292 ips, 13 msec, 3 square
waves