HP A7533A - Brocade 4Gb SAN Switch Base Administrator's Manual page 332

Hp storageworks fabric os 5.3.x administrator guide (5697-0244, november 2009)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

Example: Add filter-based monitors to slot 1, port 2 and displays the results
switch:admin> perfaddreadmonitor 1/2
SCSI Read filter monitor #0 added
switch:admin> perfaddwritemonitor 1/2
SCSI Write filter monitor #1 added
switch:admin> perfaddrwmonitor 1/2
SCSI Read/Write filter monitor #2 added
switch:admin> perfaddscsimonitor 1/2
SCSI traffic frame monitor #3 added
switch:admin> perfaddipmonitor 1/2
IP traffic frame monitor #4 added
switch:admin> perfmonitorshow --class FLT 1/2
There are 5 filter-based monitors defined on port 2.
KEY
ALIAS
----------------------------------------------------------------
0
SCSI Read
1
SCSI Write TELNET
2
SCSI R/W
3
SCSI Frame TELNET
4
IP Frame
Adding custom filter-based monitors
In addition to the standard filters—read, write, read/write, SCSI frame and IP frame—you can create
custom filters to gather statistics that fit your needs.
To define a custom filter, use the perfAddUserMonitor command. With this command, you must
specify a series of
Locates the byte found in the frame at the specified
Applies the
Compares the value with the given
Increments the filter counter if a match is found.
The following number of offsets can be specified:
NOTE:
Bloom-based switches provide 2 unique unused offsets per port for user-defined filter monitors
other than the 6 offsets already reserved for pre-defined filter monitors. Condor-based switches provide 15
unused offsets per port.
To illustrate, if you were to enter:
perfaddusermonitor 30 "4, 0xff, 0x06; 6, 0xff, 0x02; 7, 0xff, 0xd4"
The operation would be successful because offset 4 is a canned monitor and has a resource already
reserved for it. Offsets 6 and 7 would exhaust all unique filter monitor resources on port 30. Therefore, any
additional filter monitors created on port 30 would have to be canned filter monitors.
SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32 and SAN Director 2/128 models (Fabric OS
v4.0.0 or later)
Up to two different offsets per port (one offset when FICON management server mode (FMS)
is enabled).
4/64 SAN Switch, 400 MP Router and 4/256 SAN Director models (Fabric OS 5.1.0b minimum)
Up to 15 different offsets per port (14 offsets when fmsmode is enabled).
HP StorageWorks SAN Switch 2/8 EL, SAN Switch 2/16 (Fabric OS v3.0.0 or later)
Up to three different offsets per port.
SAN Switch 4/32, SAN Switch 4/32B models (Fabric OS v4.4.0 or later)
Up to 15 different offsets per port (14 offsets when FMS is enabled).
344 Administering Advanced Performance Monitoring (APM)
OWNER_APP
OWNER_IP_ADDR
TELNET
TELNET
TELNET
offsets
masks
values
,
, and
mask
to the byte found in the frame.
values
FRAME_COUNT
N/A
0x0000000000000000
N/A
0x0000000000000000
N/A
0x0000000000000000
N/A
0x0000000000000000
N/A
0x0000000000000000
. For all transmitted frames, the switch performs these tasks:
offset.
in the perfAddUserMonitor command.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents