Selecting authentication protocols

Use the authUtil command to perform the following tasks:
Display the current authentication parameters
Select the authentication protocol used between switches
Select the Diffie-Hellman (DH) group for a switch
Run the authUtil command on the switch you want to view or change. Below are the different options to
specify which DH group you want to use.
00 – Dh Null option
01 – 1024 bit key
02 – 1280 bit key
03 - 1536 bit key
04 – 2048 bit key
This section illustrates using the authUtil command to display the current authentication parameters and
to set the authentication protocol to DH-CHAP. See the Fabric OS Command Reference for more details on
the authUtil command.
To view the current authentication parameter settings for a switch:
1.
Log in to the switch as admin.
2.
On a switch running Fabric OS 5.3.0, type authUtil --show.
Output similar to the following is displayed:
AUTH TYPE
--------------------------------------
fcap,dhchap
Switch Authentication Policy: PASSIVE
Device Authentication Policy: OFF
To set the authentication protocol used by the switch to DH-CHAP:
1.
Log in to the switch as admin.
2.
On a switch running Fabric OS v4.x or v5.x, type authUtil --set -a dhchap; on a switch
running Fabric OS v3.x, type authUtil "
Output similar to the following is displayed:
Authentication is set to dhchap.
When using DH-CHAP, make sure that you configure the switches at both ends of a link.
If you set the authentication protocol to DH-CHAP, have not yet configured shared secrets, and
authentication is checked (for example, you enable the switch), switch authentication fails.

Re-authenticating ports

Use the command authutil to re-initiate the authentication on selected ports. It provides flexibility to
initiate authentication for specified E_Ports, set of E_Ports, and all E_Ports on the switch. This command will
not work on Private, Loop, NPIV and FICON devices. The command authutil can re-initiate
authentication only if the device was previously authenticated. If the authentication fails because shared
secrets do not match, the port is disabled.
This command works independently of the authentication policy; this means you can initiate the
authentication even if the switch is in PASSIVE mode. This command is used to restart authentication after
changing the DH-CHAP group, hash type, and shared secret between a pair of switches.
CAUTION:
This command may bring down the E_Port(s) if the DH-CHAP shared secrets are not installed
correctly.
HASH TYPE
GROUP TYPE
sha1,md5
0, 1, 2, 3, 4
set -a dhchap".
--
Fabric OS 5.3.0 administrator guide 133