Troubleshooting; Avertissement; Battery Checkout; Gate Not Operating - Chamberlain MEGA SLIDE-X Owner's Manual

1/2 hp commercial duty slide gate operator
Table of Contents

Advertisement

BATTERY CHECKOUT

WARNING
When the batteries become weak the gate will begin to run
noticeably slower. (NOTE: Batteries should only be checked when
you are sure they have had adequate time to fully charge.) Turn
CAUTION
off the ac power and run gate for 5 to 10 cycles while observing
low battery indicator LED D12. If LED 12 comes ON, batteries are
too weak to function properly. If LED 12 does not light, then
voltage should be checked as they still maybe near failure.
Correct voltage is approximately 25.5 Vdc. (NOTE: If LED D12
does light, gate will open to conserve batteries in this test or in a
real power loss, even if mode switch 8 on S2 is off.) Return of ac
power will clear low battery indicator. Correct charge voltage is
27.5 Vdc with batteries not connected (Set with R63, shown on
the Control Board Layout page).

AVERTISSEMENT

ATTENTION
ADVERTENCIA
PRECAUCIÓN
T R O U B L E S H O O T I N G
To prevent possible SERIOUS INJURY or DEATH from
electrocution or fire, BEFORE proceeding
• Disconnect ac power at the fuse box.
• Disconnect dc power at the battery connection.

GATE NOT OPERATING

Is the HBEAT flashing?
Is the battery lo LED on?
Is S2-8 (open on ac fail) on?
Is the shadow input active?
Is the Safety, Backaway, or Open
Does the IRD light while
Is the IRD on solid?
17
WARNING
WARNING
WARNING
Gate will not operate.
Check the battery
No
Yes
Yes
AVERTISSEMENT
No
Yes
AVERTISSEMENT
Yes
No
Yes
No
Yes
input active?
No
Make sure the gate is not binding, then
Yes
adjust the IRD. Verify the gate reverses
operating?
No
ADVERTENCIA
Yes
Is the IRD flashing?
ADVERTENCIA
No
The run timer has expired. Inspect
the belt for slippage and verify the
fast run timer settings are correct.
Re-issue a command to start the
gate.
Yes
A double entrapment (E2)
condition has occurred over 5
minutes ago. Clear all the
obstructions and use the AUX
input to reset the gate.
Check fuse F4.
connections.
Replace if blown.
Is the HBEAT
flashing now?
No
Restore ac
power and/or
turn ac
Is the ac power
power switch
No
LED on?
ON.
Is the ac power
LED on now?
No
Yes
Check fuse F3, Replace
Allow unit to
if blown.
charge before
operation.
Remove the active input to allow
the gate to open.
Remove the active input to allow
the gate to close.
when obstructed.
Is the Entrapment
Alarm On?
No
Yes
The Edge input
(JP2) is active.
Clear obstruction
to restore
operation.
Is the Entrapment
Alarm On?
No
Yes
A double entrapment (E2)
condition has recently
occurred. Clear all
obstructions and use the
AUX input to reset the alarm
and gate.