Troubleshooting - Chamberlain B2202C Installation Manual

Belt drive garage door opener
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting

Diagnostic Chart
Your garage door opener is programmed with self-diagnostic capabilities. The UP and DOWN arrows on the garage door opener flash the diagnostic codes.
DIAGNOSTIC CODE SYMPTOM
Flashes
Flashes
The garage door opener will not close.
1
1
The garage door opener will not close.
1
2
The door control will not function.
1
3
The garage door opener will not close.
1
4
Door moves 6-8" (15-20 cm) stops or reverses.
1
5
No movement, only a single click.
Opener hums for 1-2 seconds no movement.
Door coasts after it has come to a complete stop.
1
6
No movement, or sound.
2
1-5
Unable to set the travel or retain position.
3
2
The battery status LED is constantly flashing green.
3
3
Door is moving, stops or reverses. Opener beeps and lights
4
1-4
flash.
Opener runs approximately 6-8" (15-20 cm), stops and
4
5
reverses.
The garage door opener will not close.
4
6
SOLUTION
Safety reversing sensors are not installed, connected, or wires may be cut. Inspect sensor wires for a disconnected or cut wire.
There is a short or reversed wire for the safety reversing sensors. Inspect safety sensor wire at all staple and connection points, replace
.
wire or correct as needed.
The wires for the door control are shorted or the door control is faulty. Inspect door control wires at all staple and connection points,
replace wire or correct as needed.
Safety reversing sensors are misaligned or were momentarily obstructed. Realign both sensors until both LEDs are glowing steady. Make
sure nothing is hanging or mounted on the door that would interrupt the sensor's path while closing.
Manually open and close the door. Check for binding or obstructions, such as a broken spring or door lock, correct as needed. Check
wiring connections at travel module and at the logic board. Replace travel module if necessary.
Manually open and close the door. Check for binding or obstructions, such as a broken spring or door lock, correct as needed. Replace
logic board if necessary.
Manually open and close the door. Check for binding or obstructions, such as a broken spring or door lock, correct as needed. Replace
motor if necessary.
Program travel to coasting position or have door balanced by a trained door systems technician.
Replace logic board.
Check travel module for proper assembly, replace if necessary.
Battery backup charging circuit error, replace the logic board.
Manually open and close the door. Check for binding or obstructions, such as a broken spring or door lock, correct as needed. If the door
is binding or sticking contact a trained door systems technician. If door is not binding or sticking attempt to reprogram travel, see
Program the Travel page 32.
Communication error to travel module. Check travel module connections, replace travel module if necessary.
Safety reversing sensors are misaligned or were momentarily obstructed. Realign both sensors to ensure both LEDs are steady and not
flickering. Make sure nothing is hanging or mounted on the door that would interrupt the sensor's path while closing.
41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B2405cB4505tc

Table of Contents