Removing And Installing Components - Cisco MDS9120 - MDS 9120 Multilayer Fabric Switch Installation Manual

Hardware installation guide
Hide thumbs Also See for MDS9120 - MDS 9120 Multilayer Fabric Switch:
Table of Contents

Advertisement

Chapter 2
Installing the Cisco MDS 9100 Series
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Flip the power switches on the power supplies to the on (|) position. The switch boots automatically.
Step 5
Listen for the fans; they should begin operating as soon as the switch is powered on.
Step 6
Caution
Verify that the LED behavior is as follows when the switch has finished booting:
Step 7
Note
If any LEDs other than the Fibre Channel port LEDs are orange or red after the initial boot processes are
complete, see the Cisco MDS 9000 Family Troubleshooting Guide.
Try removing and reinstalling a component that is not operating properly. If it still does not operate
Step 8
correctly, contact your customer service representative for a replacement.
Note
Verify that the system software has booted and the switch has initialized without error messages. If any
Step 9
problems occur, see the Cisco MDS 9000 Family Troubleshooting Guide or the Cisco MDS 9000 Family
System Messages Guide. If you cannot resolve an issue, contact your customer service representative.
Step 10
Complete the worksheets provided in
reference.
Note

Removing and Installing Components

The Cisco MDS 9140 Switch and the Cisco MDS 9120 Switch is shipped with two field-replaceable
power supplies. Each power supply includes a fixed fan. The Cisco MDS 9140 Switch and the
Cisco MDS 9120 Switch also have two field-replaceable fan modules. The Cisco MDS 9148 Switch and
OL-21514-01
Do not operate the switch without a functioning fan module except for during the brief fan
module replacement procedure. The Cisco MDS 9000 Family switches can operate for only a
few minutes without any functioning fan modules before they begin to overheat.
Fan status LED is green.
Each power supply LED is green.
The Switch status LED is green. If this LED is orange or red, then one or more environmental
monitors is reporting a problem.
The Ethernet port Link LEDs should not be on unless the cable is connected.
The LEDs for the Fibre Channel ports remain orange until the ports are enabled, and the LED
for the MGMT 10/100 Ethernet port remains off until the port is connected.
If you purchased Cisco support through a Cisco reseller, contact the reseller directly. If you
purchased support directly from Cisco, contact Cisco Technical Support at this URL:
http://www.cisco.com/en/US/support/tsd_cisco_worldwide_contacts.html
A setup utility automatically launches the first time you access the switch and guides you
through the basic configuration. For instructions about how to configure the switch and check
module connectivity, see the Cisco Fabric Manager Fundamentals Configuration Guide.