Available languages

Available languages

Installation
Preparation - Electrical Supply
PREPARE ELECTRICAL WIRING
FOR PERSONAL SAFETY: Remove house fuse
or open circuit breaker before beginning
installation.
Do not use an extension
cord or
adapter
plug with this appliance.
PARA SEGURIDAD PERSONAL: Retire el
fusible de la casa o abra el interruptor
de
circuitos
antes de empezar la instolaci6n.
No use un cable de extensi6n
o enchufe
adaptador
con este aparato.
Electrical
Requirements
• This appliance
must be supplied
with
120V, 60 Hz.,
and connected
to an individual
properlg
grounded
branch
circuit,
protected
bg a 15- or 20-ampere
circuit
breaker
or time-delag
fuse.
• Wiring
must be 2 wire with ground.
• If the electrical
supplg
does not meet the above
requirements,
call a licensed
electrician
before
proceeding.
Grounding
Instructions
- Permanent
Connection
This appliance
must be connected
to a grounded-
metal,
permanent
wiring
sgstem,
or an equipment-
grounding
conductor
must be run with the circuit
conductors
and be connected
to the equipment-
grounding
terminal
or lead on the appliance.
Grounding
Instructions
- Power Cord Models
This appliance must be grounded. In the event of a
malfunction
or breakdown, grounding
will reduce
the risk of electric shock bg providing a path of
least resistance for electric current. This appliance
is equipped with a cord having an equipment-
grounding
conductor
and a grounding
plug. The plug
must be plugged into an appropriate
outlet that is
installed and grounded in accordance
with all local
codes and ordinances.
The improper
connection
of the equipment-
grounding
conductor
can result in electric
shock. Check with a qualified electrician
or
service representative
if gou are in doubt that
the appliance
is properlg grounded,
Do not modifg the plug provided with the
appliance;
if it will not fit the outlet° have
a proper outlet installed
bg a qualified
technician.
_La
conexi6n incorrecta
del conductor
de conexi6n a tierra del equipo puede
resuitar en choque el_ctrico.
Consulte con
un electricista
calificado
o representante
de servicio si tiene dudas de la conexi6n
a tierra del aparato.
No modifique
el
enchufe qua se suministra
con el aparato;
si no colza en el tomacorrientes0
haga
qua un t_cnico calificado
le instale un
tomacorrientes
adecuado.
,,f-
Alternate
]'\
//
I
I
Receptacle
ij \\
_,,
"
Location
Cabinet
Figure
E
White
Cabinet
Preparation
and Wire
Routing
, The wiring
mag enter
the opening
from either
side,
rear or floor within
the shaded
area illustrated
above
in Figure E and defined
in Figure A.
• Cut a 2-1/2" maximum
diameter
hole to insert the
electrical
cable. Permanent
wiring
connections
mag pass through
the same hole as the drain
hose and hot water
line, if convenient.
Hole edges
must be smooth
and rounded,
if the cabinet
wall is
metal, the hole edge must
be covered
with a cord
protector.
NOTE: Power cords with
plug must
pass through
a
separate
hole.
Protector
(Provided
with Power
Cord Hodels Onlg)
Hole Diameter
1-1/2" Haximum
Electrical
Connection
to Dishwasher
Electrical
connection
is on the right front of
dishwasher.
, For permanent
connections,
the cable must
be
routed
as shown
in Figure E. The cable
must extend
a minimum
of 24" from the rear wall.
, For power
cord connections,
install a 3-prong
grounding-tgpe
receptacle
in the adjacent
cabinet
rear wall, between
6" and 18" from the opening,
6"
to 18" above
the floor as shown
in Figure
E.