Power Wiring Connections - Chamberlain H Owner's Manual

Industrial duty door operator
Hide thumbs Also See for H:
Table of Contents

Advertisement

Remove the cover from the electrical enclosure. Inside this enclosure you will find the wiring diagram(s)
for your unit. Refer to the diagram (glued on the inside of the cover) for all connections described below.
If this diagram is missing, call the number on the back of this manual. DO NOT INSTALL ANY WIRING OR
ATTEMPT TO RUN THIS OPERATOR WITHOUT CONSULTING THE WIRING DIAGRAM.
WARNING
DISCONNECT POWER AT THE FUSE BOX BEFORE
PROCEEDING.
OPERATOR MUST BE PROPERLY GROUNDED AND
CONNECTED IN ACCORDANCE WITH LOCAL ELEC-
TRICAL CODES. NOTE: THE OPERATOR SHOULD
BE ON A SEPARATE FUSED LINE OF ADEQUATE
CAPACITY.
ALL ELECTRICAL CONNECTIONS MUST BE MADE
BY A QUALIFIED INDIVIDUAL.
WARNING
TO AVOID DAMAGE TO DOOR AND OPERATOR,
MAKE ALL DOOR LOCKS INOPERATIVE. SECURE
LOCK(S) IN "OPEN" POSITION.
IF THE DOOR LOCK NEEDS TO REMAIN FUNCTION-
AL, INSTALL AN INTERLOCK SWITCH.
CAUTION
ON THREE PHASE MACHINES ONLY!
Incorrect phasing of the power supply will cause the motor to rotate in the wrong direction (open when CLOSE but-
ton is pressed and vice-versa). To correct this, interchange any two of the incoming three phase power lines.
WARNING
Do Not Run Power &
Control Wiring in the
Same Conduit

POWER WIRING CONNECTIONS

WARNING
Three (3)7/8" & 1-1/6"dia. knockouts for Power & Control
Wiring access (Near & Opposite side)
CONDUIT ACCESS
7
POWER WIRING
1.
Be sure that the power supply is of the correct
voltage, phase, frequency, and amperage to supply
the operator. Refer to the operator nameplate on the
cover.
2.
Using the 1-1/16" dia conduit access hole as
shown below, bring supply lines to the operator and
connect wires to the terminals indicated on the
WIRING CONNECTIONS DIAGRAM.
DO NOT TURN POWER ON UNTIL YOU HAVE FIN-
ISHED MAKING ALL POWER AND CONTROL
WIRING CONNECTIONS AND HAVE COMPLETED
WARNING
THE LIMIT SWITCH ADJUSTMENT PROCEDURE.
CAUTION: THIS UNIT MUST BE PROPERLY
GROUNDED. A GROUND SCREW IS SUPPLIED IN
THE ELECTRICAL BOX FOR CONNECTION OF
THE POWER SUPPLY GROUND WIRE. FAILURE
TO PROPERLY GROUND THIS UNIT COULD
RESULT IN ELECTRIC SHOCK AND SERIOUS
INJURY.