Page 1
F A C T O R Y S E T O W N E R ’ S M A N U A L J H H J INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR This Operator Features the Enhanced PAT E N T P E N D I N G The Maintenance Alert System™...
19-50106M #50 CHAIN, 106 PITCH 02-103L3 PUSH BUTTON STATION 40-6000 DOOR OPERATOR LABEL 14-12133 PARTS BOX 77-10897 PARTS BAG K77-31334 - MODEL J 10-10893 CHAIN RETAINING BRACKET PART # DESCRIPTION QTY. 14-10466 PLASTIC BAG 19-50106M #50 CHAIN, 106 PITCH 80-207-19 KEY 1/4 X 1-1/2"LONG...
DISCONNECT: Secondary: #48 chain/sprocket; Output: #50 chain Model J . . .Floor level disconnect for manual door operation. Model H ... . .Floor level chain hoist with electrical OUTPUT SHAFT SPEED: ......36 RPM interlock for manual door operation.
• Disable ALL locks and remove ALL ropes connected to door Both J and H series operators have dual output shafts and may BEFORE installing and operating door operator to avoid be mounted on either the right (standard) or left side of door, and entanglement.
I N S T A L L A T I O N Before your operator is installed, be sure the door has been properly aligned and is working smoothly. The operator may be wall mounted or mounted on a bracket or shelf. If necessary, refer to the preparation on page 5. Refer to the illustration and instructions below that suits your application.
This operator includes both a floor level disconnect chain to disconnect the door from the door operator and a disconnect chain with manual hoist to electrically disable the operator controls. 1. Refer to Model H instructions for hoist operation. 2. Refer to Model J instructions for manual operation.
Connect operator end of coil cord to junction box (not provided) fastened to the wall approximately halfway up the door opening. A D J U S T M E N T WARNING WARNING...
A D J U S T M E N T BRAKE ADJUSTMENT WARNING WARNING A solenoid is standard on 3/4 and 1 horsepower models, and is optional on 1/3 and 1/2 horsepower models. The brake is To avoid SERIOUS PERSONAL INJURY or DEATH from...
P O W E R W I R I N G & G R O U N D W I R I N G NING WARNING WARNING To reduce the risk of SEVERE INJURY or DEATH: • ALL electrical connections MUST be made by a qualified individual.
C O N T R O L B O A R D CONTROL BOARD ILLUSTRATION Ø14LGØ657–A Ø14GPØ657–A C3Ø Auxilliary Board Motor Direction Jumper Connectors D3Ø2 P1Ø Single Phase & Three Phase Jumper Programmed Chip POWER Maintenance Alert TIMER J3ØØ TIMER DEFEAT DEFEAT System button for...
P R O G R A M M I N G LOGIC CONTROL PUSHBUTTONS OPEN, CLOSE, STOP SELECTOR DIAL Open, Close and Stop buttons are mounted directly on the Logic Control board. Thus, making it easy to program as well as have door control at the electrical box.
P R O G R A M M I N G FAILSAFE WIRING TYPES SELF-MONITORING SAFETY DEVICE OPTIONS To use the operator in any of the Failsafe wiring modes, or Timer TYPE To Close wiring modes (TS, T, FSTS), a LiftMaster self monitoring FSTS 3-Button Station, 1-Button Station, 1 &...
P R O G R A M M I N G PROGRAMMING REMOTES SINGLE BUTTON CONTROL (SBC) REMOTE This function programs a remote as a Wireless Single Button STANDARD SINGLE BUTTON REMOTE Control. In B2 mode, operation is 1. Press and release the RADIO button (LED will light). OPEN/STOP/CLOSE/REVERSE/STOP.
P R O G R A M M I N G MAINTENANCE ALERT SYSTEM (MAS) SELECTOR DIAL Feature: An internal cycle counter will activate a flashing LED on the three button control station when the preset number of cycles or months has elapsed (whichever occurs first). Setting this feature is optional.
P R O G R A M M I N G OPEN MID STOP Feature: Door will open to an installer set height that is less than fully open. SELECTOR DIAL Benefit: The door opens to a midpoint between open and close reducing heating and cooling costs.
P R O G R A M M I N G TIMER TO CLOSE PROGRAM TIMER TO CLOSE BY EXAMPLE (Method 2): SELECTOR DIAL Additional Benefit: Allows the installer to walk through a real life example to set the Timer to Close. To Program: 1.
A U T O M A T I C A L L Y L E A R N E D P R O G R A M M I N G MAXIMUM RUN TIMER (MRT) Feature: The operator will learn the distance it takes to open or close the door plus approximately 12 - 14".
O P T I O N A L P R O G R A M M I N G RESETTING FACTORY DEFAULTS - CLEARING MEMORY SELECTOR DIAL To reset most of the user installed settings back to factory defaults: 1. Turn the selector dial to DIAGNOSTIC 2.
T R O U B L E S H O O T I N G DIAGNOSTIC CHART The logic control board has several LED's to assist in the installation and troubleshooting of the operator. The following chart should assist in verifying the operator is functioning properly. Turn the selector dial to DIAGNOSTIC to keep the door from moving while troubleshooting.
TROUBLESHOOTING GUIDE FAULT POSSIBLE CAUSE ➤ THE OPERATOR WILL a) Operator control station is wired wrong Use the OPEN, CLOSE and STOP LEDs to help check correct wiring. NOT RESPOND TO ANY Verify that the board is accepting commands by using the onboard COMMANDS station.
TROUBLESHOOTING ERROR CODES LiftMaster Logic 3.0 operators incorporate a self diagnostic and press the OPEN button. To read out each individual error feature built into the MAS LED. In addition to indicating when code (if more than one exists) press CLOSE. It is possible to have routing maintenance is due, the MAS LED can be used to more than one error at a time.
R E P A I R P A R T S K I T S - M O D E L J L O G I C C O N T R O L 3 Refer to the parts lists below for replacement kits available for your operator. If optional modifications and/or accessories are included with your operator, certain components may be added or removed from these lists.
R E P A I R P A R T S K I T S - M O D E L H J L O G I C C O N T R O L 3 Refer to the parts lists below for replacement kits available for your operator. If optional modifications and/or accessories are included with your operator, certain components may be added or removed from these lists.