Control Connection Diagram - Chamberlain H Owner's Manual

Industrial duty commercial door operator
Hide thumbs Also See for H:
Table of Contents

Advertisement

IMPORTANT NOTES:
1) The 3-Button Control Station provided must be connected for operation.
2) If a STOP button is not used, a jumper must be placed between termianls 3 and 4.
3) Auxiliary control equipment may be any normally open two wire device such as
pullswitch, single button, loop detector, card key or such device.
3 BUTTON STATION or 3 POSITION KEYSWITCH w/ SPRING RETURN TO CENTER AND STOP BUTTON
STANDARD
1
2
3
Open
Close
Stop
ALL CONTROL WIRING TYPES
2 BUTTON STATION or 3 POSITION KEYSWITCH w/ SPRING RETURN TO CENTER
STANDARD
1
2
4
SEE NOTE #2
Open
Close
ALL CONTROL WIRING TYPES
SENSING DEVICE TO REVERSE OR STOP
ALL CONTROL WIRING TYPES
TIMER TO CLOSE w/ WARNING LIGHT
Warning Light will activate 15 sec. before door closes.
11
13
12
Timer Defeat
Switch
T1 CONTROL WIRING ONLY
01-30973B
C O N T R O L C O N N E C T I O N D I A G R A M
4
1
ALL CONTROL WIRING TYPES
1
2
Open
Close
ALL CONTROL WIRING TYPES
3
10
Sensing Device
14
Auxiliary Terminal Block
Power Supply for
Warning Light
©2007, The Chamberlain Group, Inc.
2 OR MORE
2
3
4
Open
Open
Close
Close
Stop
Stop
2 OR MORE
4
SEE NOTE #2
Open
Close
RESIDENTIAL RADIO CONTROLS
*
OPEN TIMER TO CLOSE
ALL CONTROL WIRING TYPES
*
T1 WIRING - RADIO TO OPEN ONLY
EXTERNAL INTERLOCK
When Interlock is Used
4
5
ONE
ALL CONTROL WIRING TYPES
All Rights Reserved
ATTENTION ELECTRICIAN:
USE 16 GAUGE OR HEAVIER WIRE
FOR ALL CONTROL CIRCUIT WIRING.
KEY LOCKOUT
1
2
3
4
Open
Close
Stop
Keyswitch
ALL CONTROL WIRING TYPES
1 BUTTON STATION or
ANY AUXILIARY DEVICE
3
7
SEE NOTES
#2 AND #3
OPEN / CLOSE
B2 or T1
WIRING TYPES ONLY
R2
R1
R3
EXTERNAL
TERMINAL BLOCK
RADIO CONTROL
Remove Jumper
4
5
2 OR MORE