Chamberlain H Owner's Manual page 16

Logic control (ver. 2.0) industrial duty door operator
Hide thumbs Also See for H:
Table of Contents

Advertisement

All modes contain: Wiring for sensing devices to reverse. Wiring for failsafe reversing devices. Connection for
electrical detection of clutch slippage. External interlocks and auxiliary devices. Open button override while door
is traveling down.
NOTE: Open, Close, and Stop buttons are located on the Logic Control board. This will provide programming
ability and door control at the electrical box.
WIRING
TYPE
STATION
C2
3 Button, 3 Button Radio Control
Function: Momentary contact to open and stop with constant pressure to close,
open override plus wiring for sensing device to reverse.
B2
3 Button, 1 Button, 1 & 3 Button Radio Control
Function: Momentary contact to open, close and stop, plus wiring for sensing
device to reverse and auxiliary devices to open and close with open override.
D1
2 Button, 3 Button Radio Control
Function: Constant pressure to open and close with wiring for sensing device to
stop.
E2
2 Button, 3 Button Radio Control
Function: Momentary contact to open with override and constant pressure to close.
Release of close button will cause door to reverse (roll-back feature) plus wiring for
sensing device to reverse.
T*
3 Button, 1 Button, 1 & 3 Button Radio Control
Function: Momentary contact to open, close, and stop, with open override and
timer to close. Every device that causes door to open, except a reversing device,
activates timer to close. Auxiliary controls can be connected to open input to
activate the timer to close. If the timer has been activated, the open button and
radio control can recycle the timer. The stop button will deactivate the timer until
the close button is used to close the door. (NOTE: Requires Optional failsafe
photo eyes to operate.)
TS*
3 Button, 1 Button, 1 & 3 Button Radio Control
Function: Momentary contact to open, close, and stop with open override and timer
to close. Every device that causes door to open, including a reversing device,
activates timer to close. Auxiliary controls can be connected to open input to
activate the timer to close. If the timer has been activated, the open button and
radio control can recycle the timer. The stop button will deactivate the timer until
the close button is used to close the door. (NOTE: Requires Optional failsafe
photo eyes to operate.)
FSTS
Momentary button contact for open, close and stop. Radio controls
allowing open, close and stop. User set midstop. User set timer to close,
functional at open limit. The single button station opens the door and activates the
timer to close, putting the operator in TS mode until the door reaches the down
limit, or is stopped in travel. At which time the operator enters the B2 mode. A
failsafe is required to operate in this mode. (NOTE: Requires Optional failsafe
photo eyes to operate.)
NOTE:
1. External interlocks may be used with all functional modes.
2. Auxiliary devices are any devices that have only one set of contacts. Examples
are: photocell, loop detector, pneumatic or electrical treadles, residential radio
controls, one button stations, pull cords, etc.
3. Open override means that the door may be reversed while closing by activating
an opening device without the need to use the stop button first.
WIRING TYPES
16
ON
ON
C2
1
2
3
OFF
ON
ON
B2
1
2
3
4
OFF
ON
ON
D1
1
2
3
4
OFF
ON
ON
E2
1
2
3
OFF
ON
ON
T
1
2
3
OFF
ON
ON
TS
1
2
3
OFF
ON
ON
FSTS
1
2
3
OFF
4
4
4
4
4