Chamberlain GH Owner's Manual

Solid state industrial duty door operator
Hide thumbs Also See for GH:

Advertisement

INDUSTRIAL DUTY DOOR OPERATOR
2 YEAR WARRANTY
Serial #
(located on electrical box cover)
Installation Date
Wiring Type
OWNER'S MANUAL
GH
SOLID STATE
L
F A C T O R Y S E T
C2 Wiring
See pages 13 & 14
for other wiring
configurations
NOT FOR RESIDENTIAL USE
41B6
LISTED DOOR OPERATOR

Advertisement

Table of Contents
loading

Summary of Contents for Chamberlain GH

  • Page 1 OWNER'S MANUAL F A C T O R Y S E T C2 Wiring SOLID STATE See pages 13 & 14 for other wiring configurations INDUSTRIAL DUTY DOOR OPERATOR 2 YEAR WARRANTY NOT FOR RESIDENTIAL USE Serial # 41B6 (located on electrical box cover) Installation Date Wiring Type LISTED DOOR OPERATOR...
  • Page 2: Specifications

    SPECIFICATIONS MOTOR ELECTRICAL TYPE: .........Continuous duty CURRENT VOLTAGE:..5V dc HORSEPOWER: ....1/2, 3/4, 1, 1-1/2 Hp AUXILIARY VOLTAGE: ...24V dc Single or Three phase CONTROL STATION: ..NEMA 1 three button station. 2 HP Three phase OPEN/CLOSE/STOP SPEED:.......1725 RPM WIRING TYPE: ....C2 (Standard) VOLTAGE: ......115-230 Single phase Momentary contact to OPEN/CLOSE/STOP plus wiring 230 Three phase...
  • Page 3: Important Safety Notes

    OPERATOR PREPARATION The GH operator may be mounted on either the right (standard) or left side of door, and in either a vertical (standard) or horizontal mounting position. Refer to the steps below if you require the hand chain and/or disconnect chain to be on the opposite side of the operator;...
  • Page 4: Operator Mounting

    OPERATOR MOUNTING Before your operator is installed, be sure the door has been properly aligned and is working smoothly. The operator may be wall mounted or mounted on a bracket or shelf. If necessary, refer to the operator preparations on page 3. Refer to the illustration and instructions below that suits your application. 1a.
  • Page 5: Emergency Manual Operation

    EMERGENCY MANUAL OPERATION This operator has provisions for manually operating the door in case of emergency or power failure. Refer to the appropriate instructions below for your model operator. Model GH CAUTION CAUTION These operators are equipped with a manual hoist.
  • Page 6: Entrapment Protection Accessories (Optional)

    ENTRAPMENT PROTECTION ACCESSORIES (OPTIONAL) SENSING EDGES IT IS STRONGLY RECOMMENDED THAT A All types of sensing edges with an isolated normally SENSING EDGE OR OTHER ENTRAPMENT open (N.O.) output are compatible with your PROTECTION DEVICE USED operator. This includes pneumatic and electric CONJUNCTION WITH THIS OPERATOR.
  • Page 7 INSTALL POWER WIRING & CONTROL STATION Before installing control station be sure to follow all warnings described below. Failure to do so may result in severe injury to persons and/or damage to operator. Do not install any wiring or attempt to run the operator without consulting the wiring diagram.
  • Page 8: Maintenance Schedule

    MAINTENANCE SCHEDULE Check at the intervals listed in the following chart. EVERY EVERY EVERY ITEM PROCEDURE 3 MONTHS 6 MONTHS 12 MONTHS Drive Chain Check for excessive slack. Check & adjust as required. Lubricate.* Sprockets Check set screw tightness Fasteners Check &...
  • Page 9 NEMA MOTOR WIRING DIAGRAMS SINGLE VOLTA G E 1/3 & 1/2HP 115V ONLY 115V Motor Purple T1-Blue T4-Yellow Grey Blue T5-Black Yellow T8-Red Cable 1 PHASE Grey BLACK/BLUE BLACK/BLUE (Not Used) 208-230V 115V Motor Motor T2-White Grey T4-Yellow Blue T4-Yellow Orange T5-Black T5-Black...
  • Page 10: Operating Mode

    OPERATING MODE TYPE STATION 3 Button, 1 Button, 1 & 3 Button Radio Control Function: Momentary contact to open, close and stop, plus wiring for sensing device to reverse and auxiliary devices to open and close with open override. 3 Button, 3 Button Radio Control Function: Momentary contact to open and stop with constant pressure to close, open override plus wiring for sensing device to reverse.
  • Page 11 STANDARD POWER & CONTROL CONNECTION DIAGRAM Solid State Board CDO - 115V, 208-230V, 1Ph L1 N Neutral 115V, 208-230V, 1Ø L2 H Hot 115V, 208-230V, 1Ø TB1- Remove Jumper Open to Install Interlock Close Open / Close Stop Sensing Device RADIO CONTROL (24V dc only) STANDARD POWER &...
  • Page 14 OPTIONAL CONTROL SETTINGS Set / Reset Maximum Run Timer Begin with door in closed position. Set dip switch to max. run timer mode. Press control station open button to operate door from closed to max. full open position without stopping. Set dip switch to desired operating mode (B2, C2, D1, E2, T, TS).
  • Page 15 ENTRAPMENT PROTECTION ACCESSORIES (OPTIONAL) SENSING EDGES IT IS STRONGLY RECOMMENDED THAT A All types of sensing edges with an isolated normally SENSING EDGE OR OTHER ENTRAPMENT open (N.O.) output are compatible with your PROTECTION DEVICE USED operator. This includes pneumatic and electric CONJUNCTION WITH THIS OPERATOR.
  • Page 16 REPAIR PARTS LIST – ELECTRICAL BOX SOLID STATE Below are replacement kits available for your operator. For replacement of electrical box, motor or brake components be sure to match model number of your unit to kit number below to ensure proper voltage requirements. Optional modifications and/or accessories included with your operator may add or remove certain components from these lists.
  • Page 17 ELECTRICAL BOX - ILLUSTRATED PARTS...
  • Page 18 Bevel Gear, 3/4” ID 24 Tooth (3HP) 15-80B9QGH Sprocket, 80B9 QGH (3HP Models) 10-10882 Hand Chain Guide See Page 16 Electrical Box 11-11105 Hand Chain Shaft, GH See Page 16 Motor 12-10029 Bearing, 3/4” I.D. See Var. Comp. Gear Reducer 12-10883...
  • Page 20: Control Connection Diagram

    CONTROL CONNECTION DIAGRAM 41B6 IMPORTANT NOTES: The 3-Button Control Station provided must be connected for operation. LISTED DOOR OPERATOR If a STOP button is not used, a jumper must be placed between termianls 4 and 5. 3 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER AND STOP BUTTON STANDARD 2 OR MORE KEY LOCKOUT...