Command details
The commands, data, and machine IDs described here are characters (ASCII).
A command is two character bytes, a machine ID is one character byte, and each item of data is an individual
character byte.
The HS-8 can use the following take numbers, folder numbers, and project numbers. However, if a number
that does not exist is specified, it will be considered an invalid command.
Take number
Folder number
Project number
INFORMATION REQUEST
Requests the controlled device to return information such as the software version.
Command
0F
Machine ID
0
Data
none
Return
INFORMATION RETURN [8F]
STOP
Places the controlled device into stop state.
Command
10
Machine ID
0
Data
none
Return
none
PLAY
Places the controlled device into play state.
To start recording while in record-ready state, use RECORD (Record).
Command
12
Machine ID
0
Data
none
Return
none
RECORD
Places the controlled device into record or record-ready state. During recording process, the command splits a
track.
Command
13
Machine ID
0
Data
2 bytes
Data 1
Data 2
0
0
0
1
0
2
・ If data other than the above is received, the HS-8 will transmit ILLEGAL [F2].
Return
none
PAUSE
Places the controlled device into play-ready state.
To pause recording, use RECORD (Record Pause).
Command
14
Machine ID
0
Data
2 bytes
Data 1
Data 2
0
1
・ If data other than the above is received, the HS-8 will transmit ILLEGAL [F2].
Return
none
999 maximum
999 maximum
99 maximum
Description
Remarks
Record
Starts recording while in record-ready state.
Record Pause
Places the controlled device into record-ready state.
Take Increment
Splits a take during recording process.
Description
Remarks
Pause On
Places the device into play-ready state.
TASCAM HS-8 RS-232C Protocol Specification
8
TEAC Corporation