If Burrs Remain In Punch Holes Using Stream Punch Gp-501 - Konica Minolta bizhub PRO C6501/C6501P Additional Information

Bizhub pro c6501 user manual additional information
Hide thumbs Also See for bizhub PRO C6501/C6501P:
Table of Contents

Advertisement

Stream Punch
2.4.2
If Burrs Remain in Punch Holes Using Stream Punch GP-
501
If you find burrs remaining in punch holes when using the Stream Punch GP-
501, lubrication is required for the die set currently used.
Lubricate it at the position illustrated below.
Reminder
Never use the oil on the general market. For the oil to be used in this pro-
cedure, please contact your service representative.
If burrs still remain in punch holes after the lubrication, apply grease to the
positions illustrated below.