Vent Terminal, Roof Installation; Optional Blower Installation - Drolet Ultra Flame DG05437/DG05447 Installation And Operating Instructions Manual

Direct vent "0" clearance gas fireplace
Table of Contents

Advertisement

ULTRA FLAME DV "0" Clearance Fireplace

VENT TERMINAL, ROOF INSTALLATION

Roof vents are required to extend at least 3 ft. above the highest point where they pass through
the roof of the building and at least 2 ft. higher than any portion within 10 feet.
• Clearance between combustible wall and vent pipe must be 2" and a radiation shield must be
used through the insulated wall.
• If the vent terminal is more than 5 feet above the roof, use roof braces to secure the whole
assembly.

OPTIONAL BLOWER INSTALLATION

See the instruction sheet included with the optional blower before proceeding with its
installation.