Refrigerator for lp-gas and electric operation
Table of Contents

Advertisement

CLEARANCES
Minimum clearances in inches to combustible materials are
G:
Top
0
K:
Side
0
L: Bottom 0
M: Rear 1
Clearance M between the rearmost part of the refngerator and
the wall behind the refrigerator
Clearance N on top of the condenser is related to the
minimum'ventilation height
See Fig 11 and examples below
Refrigerator Overall
model
dimensions
Width
Height
A
B
RM360
30 3/8
21 11/16 6 22 1/16
RM460
32 15/166 23
RM660
40 13/16 6 23
RM760
52
23
RM1300
57 15/16 6 24 15/16 6 24 11/16 57 1/8
EXAMPLES
The clearance N for the RM360 model
following way
Installation with upper and lower side vents
N=Minimum ventilation height 37 minus installation height
29 9/1 6 plus distance between condenser top and refrige-
rator top 1 1/4
N=37-29 9/16+1 1/4=8 11/16
Installation with roof vent and lower side vent
N=Minimum ventilation height 31 minus installation height
29 9/1 6 plus distance between condenser top and refrigerat-
or top 1 1/4 plus distance between roof surface and roof
vent cap 5 1/4
N=31-29 9/16+1 1/4+5 1/4=7 15/16
8
Installation
dimensions
Depth
Height
Width
C
h
W
29 9/16 20 1/4
24 11/16 6 32 1/8
21 9/16
24 11/16 6 40
21 9/16
24 11/16 6 51 3/16
21 9/16
23 7/16
derived at in the
IS
Fig. 11
Recess
dimensions
Depth
Height
Width
d
H
W
20 3/16
29 3/4
20 1/2 2
22 3/4
32 5/16
21 13/16 23 3/4
22 3/4
40 3/16
21 13/16 23 3/4
22 3/4
51 3/8
21 13/16
22 3/4
57 1/2
23 13/16 23 3/4
Fig. 12
Distance between
top of condenser to
top of refrigerator
Depth
D
e
21 3/16
1 1/4
1 1/4
1 1/4
23 3/4
1/8
1/8