13. Carefully reposition the backplane over the guide pins on each side of the hard
drive bay. Verify that all of the front panel cables are located completely within
the open area behind the backplane.
14. Securely fasten all 12 screws into the backplane. Be careful not to overtighten
them.
15. Reposition the hard drive bay module over the system fan assembly and
reconnect all cables to the backplane. Reposition cable bundles within plastic
cable holders.

Figure 53. Cable Bundles in the Hard Disk Drive Bay Module

NOTE: You must reconnect the SATA cables in the following order with the drive bay module
still positioned in an upside down manner on top of the system fan assembly as shown
SATA 1
SATA 2
SATA 4
SATA 3
16. Carefully reposition the hard drive bay module on to the server chassis, such that
the module falls within alignment slots on each side of the chassis.
32

Figure 54. SATA Cable Connection Order

®
Intel
Server System SR1670HV Service Guide