The following steps describe how to properly install the cables between a secondary Metrologic scanner and the StratosH.
The StratosH and the secondary scanner must then be configured to communicate properly. Cable installation alone does
not guarantee that the StratosH will communicate properly with the host system and secondary scanner.
Contact a Metrologic customer service representative before connecting another manufacturer's scanner to the
StratosH as a secondary scanner.
Configuration bar codes are located in the MS2x20 Stratos Series Scanner/Diva Scale Configuration Addendum
(
00-02272x) under Scanner Configuration Bar Codes: Auxiliary Port, Quick Start for a Secondary Metrologic
MLPN
Scanner.
1.
Refer to pages 16 - 23 for the type of interface (RS232, IBM 46xx, etc.) required for your application. Follow the cable
installation steps under the appropriate interface before continuing. Once the communication and power cables have
been installed follow step 2 below for the secondary scanner installation.
2.
Connect the straight end of the RS232 PowerLink AUX cable (
secondary scanner (see figure on page 26).
3.
Connect the angled end of the RS232 AUX cable (
the bottom of the StratosH.
Important: The StratosH series' aux port requires the signals; transmit, receive, RTS & CTS from the secondary scanner.
The StratosH's auxiliary port will support 5VDC devices with a 150mA maximum current. If the auxiliary device
exceeds this specification an external power supply will be required to power the auxiliary device.
The following Metrologic scanners can receive power from StratosH: the MS9520, MS9540, and the MS5145.
4.
This step is required for secondary devices that require >5VDC and/or 150mA current to operate. Skip to step 5 if
the secondary device requires ≤ 150mA 5VDC.
Plug the power supply into the secondary scanner's PowerLink cable (
secondary scanner.
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet.
The outlet should be located near the equipment and be easily accessible.
5.
Configure the StratosH and the secondary scanner. The auxiliary input port's data format must match the main output
format of the secondary scanner.
Refer to the MS2x20 Stratos Series Scanner/Diva Scale Configuration Addendum (
Scanner Configuration Bar Codes: Auxiliary Port, Quick Start for a Secondary Metrologic Scanner.
M
ECONDARY
ETROLOGIC
S
)
CANNER
57-57099x-3) to the RS232 into the socket of the
MLPN
57-57099x-3) into the 10-pin socket labeled Aux RS232 In, on
MLPN
MLPN
57-57099x-3) and connect AC power to the
00-02272x) under