Features And Specifications - IBM 8676G1X User Manual

User manual
Table of Contents

Advertisement

Features and specifications

The following table provides a summary of the features and specifications of your
xSeries 335 Type 8676 server. Depending on your server model, some features and
specifications might not apply.
Table 1. Features and specifications
Microprocessor:
®
®
v Intel
Pentium
4 microprocessor
– Minimum: One
– Maximum: Two
v 512 KB Level-2 cache
v 400 MHz front-side bus (FSB)
Memory:
v Type: error correcting code
(ECC), double-data rate (DDR)
SDRAM, registered DIMMs with
Chipkill
– Minimum: 512 MB
– Maximum: 4 GB (8 GB with
availability of 2 GB DIMMs)
v Four slots, interleaved
Drives standard:
v Diskette: 1.44 MB
v CD-ROM: IDE
Hard disk drives:
v Slim-high drives, hot-swap SCSI
or non-hot-swap IDE (drive
capacity and speed vary with
model)
v Maximum: Two
Expansion slots:
v One full-length adapter slot
supports up to 100 MHz/64-bit
PCI-X adapters (bus A)
v One half-length adapter slot
supports up to 100 MHz/64-bit
PCI-X adapters (bus B) or 33
MHz 32-bit PCI adapters (bus C)
v Supports 3.3 V or universal
adapters only
Power supply:
One 331 watt (115-230 V ac)
Video:
v ATI RageXL video controller
integrated on system board
v Compatible with SVGA
v 8 MB SDRAM video memory
Size
v Height 43 mm (1.69 in.)
v Depth: 660 mm (25.98 in.)
v Width: 440 mm (17.32 in.)
v Weight: approximately 12.7 kg (28
lb) when fully configured
Integrated functions:
v Integrated system management
processor (ISMP) with one ISM
connector
v One LSI Ultra320 SCSI controller
with RAID level-1 capability
v Two Broadcom 10/100/1000
Ethernet controllers with Wake on
®
LAN
and Alert Standard Format
support
v Three Universal Serial Bus (USB)
ports
v One serial port
v Two Cable Chaining Technology
(C2T) ports (one IN, one OUT)
Acoustical noise emissions:
v Declared sound power, idling: 6.5
bels
v Declared sound power, operating:
6.5 bels
Chapter 1. Introducing the xSeries 335 Type 8676 server
Environment:
v Air temperature:
°
– Server on: 10
to 35°C (50.0° to
95.0°F). Altitude: 0 to 914 m
(2998.7 ft)
– Server on: 10° to 32°C (50.0° to
89.6°F). Altitude: 914 m (2998.7 ft)
to 2133 m (6998.0 ft.)
– Server off: 10° to 43°C (50.0° to
109.4°F). Maximum altitude: 2133
m (6998.0 ft)
v Humidity:
– Server on: 8% to 80%
– Server off: 8% to 80%
v Airflow rates:
– Minimum: 31.4 CFM
– Maximum: 39.2 CFM
Heat output:
Approximate heat output in British
thermal units (Btu) per hour:
v Minimum configuration: 375 Btu (110
watts)
v Maximum configuration: 1195 Btu
(350 watts)
Electrical input:
v Sine-wave input (50-60 Hz) required
v Input voltage low range:
– Minimum: 100 V ac
– Maximum: 127 V ac
v Input voltage high range:
– Minimum: 200 V ac
– Maximum: 240 V ac
v Input kilovolt-amperes (kVA),
approximately:
– Minimum: 0.110 kVA
– Maximum: 0.350 kVA
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

8676m1xEserver xseries 335 type 8676

Table of Contents