Installing the MX960 High-Capacity Tray and Filter

12
To remove the air filter (see Figure 11 on page 12):
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
1.
the strap to one of the ESD points on the chassis.
Unwrap any cables on the standard cable manager and remove the cables from the
2.
tray. Arrange the cables so that they do not block the front of the cable manager and
tray, and secure them with temporary fasteners so that they are not supporting their
own weight as they hang from the connector.
NOTE: Removing the cables from the extended cable manager is not
necessary to access the air filter.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do
not allow fastened loops of cable to dangle, which stresses the cable at
the fastening point.
Simultaneously pull the two releases labeled
3.
Lift it up and outward to lock it in place to access the air filter.
Slide the air filter tray out of the chassis.
4.
Lift the air filter out of the air filter tray.
5.
Figure 11: Removing the Air Filter
Preventing Electrostatic Discharge Damage to an MX960 Router
Installing the MX960 Air Filter
Maintaining the MX960 Air Filter
To install the air filter (see Figure 12 on page 13);
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
1.
the strap to one of the ESD points on the chassis.
Ensure that the air filter is right side up.
2.
Place the air filter into the air filter tray.
3.
on the standard cable manager.
PULL