Wall Mounted Thermostat Wiring For 120/240 Volt - Dimplex BF33ST/DX Installation Manual

Dimplex electric fireplace installation guide
Hide thumbs Also See for BF33ST/DX:
Table of Contents

Advertisement

NOTE:
Before installing the unit complete the following:
1. Install main power connection with appropriate voltage as per Section C or
Section D.
2. Install a 2 conductor wire with ground (3 wires total) from the thermostat wall box to the
junction box on the unit.
NOTE:
Wiring of the thermostat must be completed prior to installing the unit.
NOTE:
The following installation instructions are for a single pole thermostat.
120 / 240VOLT INSTALLATIONS
1. Loosen the screw securing the junction box and remove the cover.
2. Remove the knockouts (if necessary) or use the provided cable clamp.
3. Pull out the three wires marked 1, 2, and G. (red, red, and green).
4. Remove the wire connector and separate the wires marked 1 & 2.
5. Connect the (red) 1 wire from the unit to the white (neutral) wire from the wall
thermostat box by using a wire connector. (not supplied)
6. Connect the other end of the white (neutral) wire from the thermostat wall box to the red
wire from the wall thermostat.
7. Connect the (red) 2 wire from the unit to the black wire from the thermostat wall box by
using a wire connector. (not supplied)
8. Connect the other end of the black wire from the thermostat wall box to the black wire
from the wall thermostat.
9. Connect the green (ground) wire from the unit to the green (ground) wire from the
thermostat wall box by using a wire connector. (not supplied)
10. Connect the other end of the green (ground) wire to the thermostat wall box ground
screw.
11. Ensure that all connections are tight.
12. Insert all the wiring of the wall mounted thermostat into the wall box.
13. Insert all the wiring back into the unit and secure with a cable clamp.
WALL MOUNTED THERMOSTAT WIRING
FOR 120/240 VOLT
15

Hide quick links:

Advertisement

Table of Contents
loading