Clock Timezone; Mac Address And Mac Database Commands - NETGEAR GSM7212 - ProSafe Switch Cli Reference Manual

Layer-2 switches, software version 6.0
Hide thumbs Also See for GSM7212 - ProSafe Switch:
Table of Contents

Advertisement

Command Line Interface Reference for the ProSafe 7200 Series Layer-2 Switches, Software Ver-
Port
Last Attempt
Time
Last Attempt
Status
Total Unicast
Requests
Failed Unicast
Requests

4.3.12 clock timezone

When using SNTP/NTP time servers to update the switch's clock, the time data received
from the server is based on Coordinated Universal Time (UTC) which is the same as
Greenwich Mean Time (GMT). This may not be the time zone in which the switch is
located. Use the clock timezone command to configure a time zone specifying the number
of hours and optionally the number of minutes difference from UTC. To set the switch
clock to UTC, use the no form of the command.
Format
Parameters
Mode
Default

4.4 MAC Address and MAC Database Commands

This section describes the commands you use to configure and view information about the
system MAC address and the MAC address table.
4-16
Server Port Number
Last server attempt time for the specified server.
Last server attempt status for the server.
Number of requests to the server.
Number of failed requests from server.
zone-name +/-hours-offset [+/-minutes-off-
clock timezone
set]
[no] clock timezone
Zone name A name to associate with the time zone
Hours-offset Number of hours difference with UTC
Minutes-offset Number of minutes difference with UTC
Global Config
[no] clock timezone
v1.0, February 2007
Port and System Setup Commands