Install The Switch - NETGEAR GSM5212P Hardware Installation Manual

Managed switch
Hide thumbs Also See for GSM5212P:
Table of Contents

Advertisement

The site where you install the switch may greatly affect its performance. Before installing the
switch or switches, make sure that the chosen installation location meets the following site
requirements.
Table 2. Site Requirements for Switch Location
Requirements
Mounting
Access
Power source
Environment
Temperature
Operating humidity
Ventilation
Cabling

Install the Switch

You can install the switch on a flat surface or in a standard 19-inch rack.
Installing the Switch on a Flat Surface
The switch ships with four self-adhesive rubber footpads. Stick one rubber footpad on
each of the four concave spaces on the bottom of the switch. The rubber footpads
cushion the switch against shock and vibrations.
Installing the Switch in a Rack
To install the switch in a rack, you will need the 19-inch rack-mount kit supplied with your
switch.
1.
Attach the supplied mounting brackets to the side of the switch.
NETGEAR Managed Switch
• Desktop Installations: Provide a flat table or shelf surface.
• Rack-mount Installations: Use a 19-inch (48.3-centimeter) EIA standard
equipment rack that is grounded and physically secure. You need the
rack-mount kit supplied with your switch.
Locate the switch in a position that lets you access the front panel RJ-45 ports,
view the front panel LEDs, and access the rear-panel power connector.
Provide a power source within 6 feet (1.8 meters) of the installation location.
Power specifications for the switch are shown in
AC outlet is not controlled by a wall switch, which can accidentally turn off power
to the outlet and the switch.
Install the switch in a site free from strong electromagnetic field generators (such
as motors), vibration, dust, and direct exposure to sunlight.
The ambient switch operating temperature range is 0º to 50ºC (32º and 122ºF).
Keep the switch away from heat sources such as direct sunlight, warm air
exhausts, hot-air vents, and heaters.
Install the switch in a dry area with a maximum relative humidity of 90%,
noncondensing.
Do not restrict airflow by covering or obstructing air inlets on the sides of the
switch. Keep at least 2 inches (5.08 centimeters) free on all sides for cooling. Be
sure that there is adequate airflow in the room or wiring closet where you intend
to install the switch.
Route the cable to avoid sources of electrical noise such as radio transmitters,
broadcast amplifiers, power lines, and fluorescent lighting fixtures.
Hardware Installation
13